Middleby Marshall PS520 installation manual IV. Electric Supply for Electrically Heated Ovens

Page 17

These ‘C’ Channel brackets are installed in the vertical plane using existing screws (Item 6) to support these ‘C’ Channels using the upper and lower Key Hole openings in the ‘C’ Channels. The ‘C’ Channels are identical and once installed will allow ample amounts of air through the cooling fan mounted on the rear side of the ovem by keeping the oven away from the rear wall.

If you have any questions about how to mount these two ‘C’ Channel brackets, kindly phone Middleby Technical

Services at 847-741-3300. Press 3, then 5 for Technical Support.

III.ELECTRICAL CONNECTION INFORMATION FOR PS520-SERIES OVENS.

WARNING

Authorized supplier personnel normally ac- complish the connections for the ventilation system, electric supply, as arranged by the customer. Following these connections, the factory-authorized installer can perform the initial startup of the oven.

Check the oven data plate (Figure 2-10) before making any electric supply connections. Electric supply connections must agree with data on the oven data plate.

NOTE: The electric supply installation must satisfy the requirements of the appropriate statutory authority, such as the National Electrical Code (NEC), ANSI/NFPA70, (U.S.A.); the Canadian Electrical Code, CSA C22.2; the Australian Code AG601; or other applicable regulations.

SECTION 2

INSTALLATION

A fused disconnect switch or a main circuit breaker (customer furnished) MUST be installed in the electric supply line for each oven; it is recommended that this switch/ circuit breaker have lockout/tagout capability. The electric supply connection must meet all national and local electrical code requirements. Copper is the recom- mended material for the electrical supply conductors.

IV. ELECTRIC SUPPLY FOR ELECTRICALLY HEATED OVENS

Power requirements for electrically heated ovens are usually 208 - 240VAC, 1-phase, 3-wire (2 ‘hot’, 1 ground), although ovens built for export can have power require- ments of 380VAC and 480VAC. (These ovens have a 4-wire system.) A 1.5(38mm) diameter cutout/hole in the back of the machiney compartment provides access for the electrical supply connections on 380V and 480V units. 208V and 240V units have a cord and plug. Using flexible cable(s) for the electrical power supply conductors re- quires a 2(51mm) strain-relief fitting (not furnished) to enable safe access to the terminal block from which oven power is distributed.

The supply conductors must be of the size and material (copper) recommended to provide the cur- rent required; (refer to the data plate for the ampere specifications). The electric current rating for each conductor supplying a PS520-Series Oven ranges from a minimum of 17.3 amperes to a maximum of 39.9 amperes.

Typical specifications for each PS520-Series Oven are 208V or 240V, 1-phase, 3-wire, 8.3kW; this oven requires 50-ampere service. A PS520-Series Double Oven (Figure 1-2) installation would require two 50-ampere service connections, one for each oven; the 8.3kW power con- sumption also doubles for such an installation to 16.6kW.

The 208V or 240VAC electrically heated oven uses two legs of the supplied power to provide 208V or 240VAC power for the oven control circuitry.

Figure 2-10. Typical Electric Oven Data Plate

Figure 2-11. Junction Connection Box

13

Image 17
Contents Owners operating Page Middleby Marshall Table of Contents Model Identification Section DescriptionThis Manual Must Be Kept For Future Reference PS520 Series Oven SpecificationsSeries PS520 Electrical Specifications PS520-Series Oven Components Locations II. Component Function Cooling Fan F2. Blank Plates Blank Plates two sizes and an Air FingerUnloading Section InstallationSingle and Double Stack Ovens Parts List for Series PS520 Electric Oven Installation KITModel PS520 Single Oven Dimensions Model PS520 Double Oven Dimensions Model 520 Triple Oven Dimensions Electric Supply to be Provided by Customer Circuitbreaker II. Ventilation Guidelines10. Typical Electric Oven Data Plate IV. Electric Supply for Electrically Heated OvensSection Installation Control Functions Section OperationII. Component Information and Location Figures 3-1 Conveyor Measuring Conveyor SpeedIII. STEP-BY-STEP Operation Startup Procedures Daily StartupControl Panel IV. Normal Operation STEP-BY-STEP Daily Startup ProcedureSP Lock Symptom Quick Reference TroubleshootingSection Maintenance Exterior Maintenance DailyCooling Fan Conveyor Belt FigureRemoving Conveyor From Oven For Cleaning II. Maintenance MonthlyAir Fingers Disassembly For Cleaning T1 T2 T3 B1 B2 B3 12. Standard Lower Finger Reassembly of Air FingersExtended Lip Tab on Outer Plate Flange Finger Manifold Section Maintenance Reinstall End Plugs Checking Conveyor Belt Tension Conveyor Reassembly Into OvenConveyor Belt Link Removal Attaching Drive Chain IV. Maintenance Every 6 Months III. Maintenance Every 3 MonthsImportant Notices Electrical TerminalsPS520-SERIES Electric Oven KEY Spare Parts KIT Figure KEY Spare Parts KITSection Troubleshooting Section Troubleshooting Parts List English Single Oven Exploded View English Relay Panel English Blower Assembly English Control Panel English Single Conveyor Section Parts List Section Electrical Schematics Wiring Diagram, E380-480V 50/60/1, PS520 Wiring Diagram, E230-240V CE PS520/1820S Wiring Diagram, E380-400V CE PS520/1820S Section Electrical Schematics