A. Main On/Off Button

Turns all oven functions on or off. If the oven is below the set point, it will rise to the set point and turn the conveyor on. If it is turned off and the oven is above 200° F, the blowers will remain on until the oven drops below 200° F.

B. Conveyor Time Setting

Adjusts and displays the conveyor bake time. Dual belt ovens have two displays, single units have one.

C. Temperature Control/Display

Displays the average set point of both right and left sides of the oven. Pressing on the display allows individual temperature displays and adjustments.

D. Message Bar

Displays messages during oven operation.

E. Energy Level Indicators

Displays energy usage on left and right sides of the oven.

19

P/N 60254 September 28, 2012

Image 23
Contents Owners Operating and Installation Manual Retain this Manual for Future Reference Middleby Marshall Table of Contents Not Shown Conveyor Drive Motor Moves the conveyorOven Specifications Installation Parts List for Series PS740 Electric Oven Installation KIT PS740 24″ Oven Installation Required Kits and EquipmentPS740 Oven Installation Required Kits and Equipment Item no QTY Description 66159 ″-16 × 1 HEX SCREW, SST 3B. Model PS740 32 Double Oven Option Base with Legs and Top Quad Outrigger Weldment 7A2S15 SCR, MS STR Trshd 10-32X3/4″ Other ventilation concerns III. Ventilation SystemRequirements RecommendationsTop Panel and Base Pad Assembly IV. AssemblyStacking Restraint Cable InstallationDo not Overtighten the Conveyor Belt Conveyor InstallationConveyor Belt Reversal Resetting Direction JumperSwitching Photo Detector Final Assembly18. Utility Connection Locations for Elec IV. Electric Supply for Electrically Heated OvensElectric Supply to be Provided by Customer Circuit Breaker Do not USE Conduit for Ground ConnectionLocation and Description of Controls II. Normal Operation STEP-BY-STEP Screen Alerts III. Quick Reference TroubleshootingMaintenance Daily MaintenanceTop Row Bottom Row II. Maintenance MonthlySplit Belt Disassembly and Cleaning III. Maintenance Every 3 MonthsBlower Belt IV. Maintenance Every 6 MonthsItem QTY Description KEY Spare Parts Available separately. See FigureProblem Problem Oven does not HeatWiring Diagram 60741 Rev. L 60254 September 28 60254 September 28 Installing or servicing this equipment