3
RF OUTPUT
50 OHM 250W
16
REMOTE CONTROL | SCA 2 |
|
| 1 GND | MONO | 50 | MPX | |
SCA 3 | SCA 1 | |||||||
2 + |
| 75 | ||||||
6 | 7 | 8 |
| 3 - |
| S | 14 | |
|
|
| ||||||
4 |
|
|
|
|
|
|
| |
9 | 10 | 11 |
| 13 |
| 12 | 15 | |
INTERLOCK |
|
|
|
|
|
|
| |
5 |
|
|
|
| MAINS V |
| ||
|
|
|
|
|
| |||
WARNING |
|
|
|
|
|
|
| |
Voltages under equipment cover plate |
| A |
|
|
| |||
can be hazardous to your life. Equipment |
|
| 1 | CE | ||||
only can be handled by qualified personnel. |
|
| 2 |
|
1 - MAIN SUPPLY CONNECTOR
2 - AC FUSE 3A
3 - FAN
4 - DB 9 PIN INPUT / OUTPUT CONNECTOR FOR TELEMETRY ( opt.01 )
5 - BNC FEMALE FOR CONNECTION OF THE INTERLOCK LOOP - A CONNECTION TO GROUND INHIBIT RF POWER
12 - XLR FEMALE BALANCED MODE MONO AUDIO INPUT
13 - MONO INPUT ADJUSTING LEVEL
14 - BNC FEMALE FOR THE COMPOSITE MPX INPUT
15 - MPX INPUT ADJUSTING LEVEL
16 - N FEMALE FOR RF OUTPUT POWER
TITLE
NICOM
Nt250 EXCITER
REAR PANEL LAYOUT
DATE
JULY 2001
DRAWING NO.
Nt250 Rear Panel.cdr