Lincoln 1921, 1922 CAPACITOR, Conveyor Motor Replacement, AIR Pressure Switch Replacement

Page 12

CAPACITOR, CONVEYOR MOTOR – REPLACEMENT

1.Shut off power at main breaker.

2.Remove control box top. Remove tube from air pressure switch.

3.Remove wiring from air pressure switch and conveyor motor capacitor and mark all wires for reassembly.

4.Remove two screws and remove air pressure switch/capacitor mounting bracket.

5.Remove capacitor from mounting bracket.

6.Reassemble in reverse order and check system operation.

CONVEYOR MOTOR – REPLACEMENT

1.Shut off power at main breaker.

2.Remove coupling from conveyor shaft (one screw at end of motor shaft).

3.Remove control box top and rear control box cover.

4.Remove three screws and remove main control board and mounting bracket.

5.Disconnect wiring for motor and remove motor mounting screws. Remove conveyor motor and mounting bracket.

6.Remove conveyor motor from mounting bracket.

7.Reassemble in reverse order and check system operation.

AIR PRESSURE SWITCH – REPLACEMENT

1.Shut off power at main breaker.

2.Remove control box top. Remove tube from air pressure switch.

3.Remove wiring from air pressure switch and conveyor motor capacitor and mark all wiring for reassembly.

4.Remove two screws and remove air pressure switch/capacitor mounting bracket.

5.Remove air pressure switch from mounting bracket.

6.Reassemble in reverse order and check system operation.

AIR PRESSURE SWITCH – ADJUSTMENT

1.Apply power to machine, set temperature control to maximum temperature.

2.Allow 30 minute preheat. Adjust air pressure switch so that switch will stay closed at maximum temperature.

3.Remove air tube from air pressure switch and verify that switch opens.

4.Reconnect air tube and check system operation.

THERMOCOUPLE – REPLACEMENT

1.Shut off power at main breaker.

2.Remove control box top. Remove rear cover. Remove right side heating element cover.

3.Remove mounting screws and remove thermocouple from oven cavity.

4.Disconnect thermocouple from main control, remove thermocouple.

5.Remove connector plug from new thermocouple and mark wires for reassembly. Install thermocouple and reassemble plug connector.

6.Reassemble in reverse order and check system operation.

12

DTF – 1920 Series Service Manual

Image 12
Contents Dual Technology Finisher Dual Technology Finisher Schematic Diagram Model 1922 S/N 8001207 and Below Model 1921 / 1922 S/N 8001208 and Above Troubleshooting Guide With Power on and Thermocouple Digital multimeter Page MOTOR, Main FAN Replacement Main FAN ReplacementSWITCH, ON/OFF SWITCH, Standby Replacement RELAY, Time Delay ReplacementCircuit BREAKER, Main Motor Replacement Fuse Holder ReplacementRELAY, Main Heater RELAY, Infrared Heater Replacement Reversing SWITCH, Conveyor ReplacementCAPACITOR, Conveyor Motor Replacement Conveyor Motor ReplacementAIR Pressure Switch Replacement AIR Pressure Switch AdjustmentTHERMOSTAT, HI-LIMIT Replacement Heating ELEMENT, Main ReplacementHeating ELEMENT, Infrared Replacement Main Control ReplacementPage This page intentionally left blank General View Page Control BOX View Page Rear View Page Conveyor Model 1921 8001200 and Above