| sensor (sensor is located in the conveyor motor). |
|
| Measure voltage at the motor connector, red wire and |
|
| yellow wire. Voltage should be approx. 10VDC. If no |
|
| voltage is present, trace wiring back to oven control. If |
|
| there is no voltage output at the oven control, replace |
|
| oven control. |
| Conveyor motor | If there is voltage supplied to the hall effect sensor, |
|
| check for a frequency output from the hall effect sensor. |
|
| Measure frequency across the yellow and white wires in |
|
| the motor connector. Frequency reading should be |
|
| approx. |
|
| replace conveyor motor. If the readings are achieved, |
|
| proceed. |
| Oven control | If the hall effect sensor readings are correct, but there is |
|
| no speed indicated on the display, replace the oven |
|
| control. |
Impinger I – Adv Digital – Gas Service Manual – International | 11 |