| WITH POWER OFF: Remove 3 prong plug (on gas |
|
| valve) and measure continuity between terminals 2 and |
|
| 3. If no continuity, check the following: Proper gas |
|
| pressure supply to gas valve as marked on the oven |
|
| specification plate. Check for proper adjustment of the |
|
| gas pressure switch, 10 for Nat. gas, 27 for LP gas or |
|
| 4.5 for town gas. Check the filter in the gas valve for |
|
| blockage or damage. If above checks are okay, but |
|
| pressure switch is still not closed, replace gas valve. |
| Ignition control | Check for supply voltage to ignition control at terminal |
|
| #1 and neutral. If no voltage is present, trace wiring back |
|
| to gas pressure switch. If voltage is present, check for |
|
| supply voltage to burner blower motor at terminal #6 and |
|
| neutral. If no voltage is present, wait 30 seconds, reset |
|
| ignition control, and re- try. If the above fails, replace |
|
| ignition control. |
| Burner reset switch | Switch is normally open. Check to see that the switch |
|
| closes when reset button is pushed. Replace as needed. |
| Burner blower motor | Check for supply voltage to burner blower motor. If no |
|
| voltage is present, trace wiring back to the ignition |
|
| control. |
|
| WITH POWER OFF: Turn blower wheel to check for |
|
| locked rotor. |
|
| If supply voltage is present and motor does not run, |
|
| replace burner blower motor. |
| Burner blower motor air | Check for supply voltage switching to terminal NO as the |
| pressure switch | air pressure switch closes. Check for air tube blockage |
|
| or misalignment, adjust air pressure switch. If the above |
|
| fails, replace air pressure switch. |
| Spark generator | After a |
|
| blower motor starts, check for supply voltage to spark |
|
| generator. If voltage is not present, check burner reset |
|
| switch. If voltage is still not present, replace ignition |
|
| control. If voltage is present, visually check for spark at |
|
| igniter. |
| Igniter/sensor assembly | Check for visible damage to the igniter/sensor assembly. |
|
| If there is no visible damage to the components, and no |
|
| spark, replace the spark generator. If there is visible |
|
| damage to the igniter/sensor assembly, replace. Also |
|
| check for frayed or damaged wires in burner tube. |
| Gas valve | Check for supply voltage to gas valve. If no voltage is |
|
| present, check reset button. Check all connections for |
|
| tightness. If there is still no voltage at the gas valve, |
|
| replace ignition control. If there is voltage present, check |
|
| for gas pressure at gas pressure tap located in gas |
|
| piping. If there is no gas pressure, replace gas valve. |
Flame will not stay on | Flame sensor | Check for flame sensor operation, connect a digital |
|
| multimeter (capable of measuring DC microamps) |
|
| between the flame sensor wire and terminal #1 on the |
|
| ignition control. Sensor current is to be 3 microamps, |
|
| minimum. If these readings are not achieved, replace |
|
| igniter/sensor assembly. Also check for any type of |
|
| damage to flame sensor wire and connections. |
|
| NOTE: The DC microamp test must be conducted with |
|
| the oven in low flame (bypass) operation. |
| Power supply | Set the temperature to the lowest temperature setting. If |
|
| there is sufficient microamp current, but the flame will |
|
| not stay on, check for proper polarity of the power |
|
| supply. |
| Ignition control | If there is sufficient microamp current, and there is |
|
| proper polarity of the power supply, but the burner will |
Impinger I – Adv Digital – Gas Service Manual – International | 7 |