Lincoln 1454, 1455, 1421-000-E service manual Impinger Advantage Series, Belt JAM

Page 8

 

 

plug to be sure it is firmly in receptacle. Measure

 

 

incoming power, call power co. if required.

 

Fuse, 10 Amp

Check, replace if necessary.

 

Fuse holder

Check, replace if necessary.

 

Switch, oven power

Check for line voltage supplied to switch. If no voltage

 

 

is present, trace wiring back to fuse holder. Check

 

 

continuity between switch terminals. Replace switch as

 

 

needed.

 

Control transformer

Check for supply voltage to primary of control

 

 

transformer. If no voltage is present, trace wiring back to

 

 

oven power switch. If voltage is present, check for

 

 

24VAC at transformer secondary. If there is primary

 

 

voltage, but no secondary voltage, replace control

 

 

transformer.

 

Conveyor motor

Check for supply voltage to the conveyor motor at

 

 

terminal #8 to neutral. If no voltage is present, trace

 

 

wiring back to oven power switch. If voltage is present,

 

 

but the motor will not run, check the motor windings for

 

 

opens or shorts. If any of the above checks fail, replace

 

 

conveyor motor.

 

Capacitor, conveyor motor

Check for shorts or grounds. Replace capacitor as

 

 

needed.

 

 

WARNING: Capacitor has a stored charge, discharge

 

 

before testing.

 

Switch, conveyor reversing

Check continuity between switch terminals. Replace

 

 

switch as needed.

 

Oven control

If there is voltage supplied to the motor, and the motor

 

 

capacitor and reversing switch check good, replace the

 

 

oven control.

Conveyor motor runs,

NOTE: Display will indicate

 

but there is no speed

“BELT JAM”

 

display

 

 

 

Oven control

Check for output voltage from oven control to hall effect

 

 

sensor (sensor is located in the conveyor motor).

 

 

Measure voltage at the motor connector, red wire and

 

 

yellow wire. Voltage should be approx. 10VDC. If no

 

 

voltage is present, trace wiring back to oven control. If

 

 

there is no voltage output at the oven control, replace

 

 

oven control.

 

Conveyor motor

If there is voltage supplied to the hall effect sensor,

 

 

check for a frequency output from the hall effect sensor.

 

 

Measure frequency across the yellow and white wires in

 

 

the motor connector. Frequency reading should be

 

 

approx. 25-100 Hz. If these readings are not achieved,

 

 

replace conveyor motor. If the readings are achieved,

 

 

proceed.

 

Oven control

If the hall effect sensor readings are correct, but there is

 

 

no speed indicated on the display, replace the oven

 

 

control.

 

REMOVAL, INSTALLATION & ADJUSTMENTS

 

IMPINGER ADVANTAGE SERIES

 

CAUTION!

 

BEFORE REMOVING OR INSTALLING ANY COMPONENT IN THE IMPINGER

 

OVEN BE SURE TO DISCONNECT ELECTRICAL POWER AND GAS SUPPLY

8

Impinger I -–Adv Digital – Electric Service Manual - International

Image 8
Contents Impinger Conveyor Ovens Phase Power SupplyTemperature Control Control BOX AutoModel 220/380VAC 50 HZ Schematic Diagram Serial Number N28654 and Above Troubleshooting Guide Symptom Possible Cause Evaluation With Power on and Thermocouple Before Removing or Installing ANY Component in the Impinger Oven be Sure to Disconnect Electrical Power and GAS SupplyImpinger Advantage Series Belt JAMFAN Spider FAN HUB Cone THERMOSTAT, Oven Cavity HI-LIMIT Replacement AIR Pressure Switch ReplacementThermocouple Type K Replacement Thermocouple Measurment Temperature Millvolts ApproxControl Transformer Replacement Conveyor Drive Motor ReplacementCAPACITOR, Conveyor Motor Replacement Reversing Switch ReplacementFuse Holder Replacement BEARING, Conveyor ReplacementHeat Contactor Replacement HI-LIMIT Contactor ReplacementTHERMOSTAT, Control BOX HI-LIMIT Replacement General View Advantage Series Letter Part Number DescriptionPage Control BOX Letter DescriptionPage Oven Back GAS and ElectricPage Conveyor SeriesPage This page intentionally left blank This page intentionally left blank