APW Wyott Status, Alarm, and Error Messages See Figure, VSX-10 Temperature Control See Figure

Page 5

Status, Alarm, and Error Messages (See Figure 3)

rdY Control is at set point and the toaster is ready for operation.

Lo Actual temperature is below set point. After toaster has reached “rdY,” then this indicates that the platen is less than 50°F below the set point (too cold).

Hi Actual temperature is above set point.

Prb The temperature probe (sensor) is disconnected or defective.

HIE Actual temperature is at least 50°F above set point, indicating that there is a controller error.

FIGURE 4: TYPICAL

TOASTER OPERATION

HEEL IN

CROWN

BACK

IN FRONT

 

 

BUN

 

DISCHARGE

FIGURE 5:

VSX-20 W/BUN CATCHER

“If you like to keep your counter clean, APW Wyott also offers a bun catcher. This is a bun chute that will catch the crumbs that fall down the bun chute. The bun catcher is part number 81699002.”

VSX-10 Temperature Control (See Figure 6)

NO HEAT:

When the knob is pointed here, all heat is cut off from the

 

platen. The conveyors will run, but the platen will not heat.

PILOT:

Illuminated when power is being applied to heater.

KNOB:

Used to select the set point. Graduations are °F.

POWER:

Main power supply to the toaster.

Operation of Controller (See Figure 6)

1.Make sure that all the doors are closed and the lid is on. (It should look like the photograph on the cover.)

2.Make sure toaster is plugged in to the5correct voltage. The voltage of the toaster is written on the data plate. The data plate is located on the back of the toaster near the cord.

3.Turn the toaster on (POWER). “” is on and “O” is off.

4.Turn the dial to the desired set point. APW recommends that you set it to 600°F or below. If the dial is set to “NO HEAT” then the toaster will run normally except that there will be no more heat supplied to the toaster. The toaster will cool down to room temperature.

5.Whenever heat is applied to the platen, the PILOT light will be illuminated. When the pilot light has cycled a couple of times (turned off and on, twice), then the toaster is ready for toasting. This takes 10-15 minutes.

FIGURE 6:

VSX-10

TEMP. CONTROL

PILOT

Image 5
Contents ’VertTM Installation Operating InstructionsSafety Information Table of ContentsOverall Dimensions Electrical Ratings Cordset ConfigurationSPE Ific Tions 23.90 22.64VSX-20 Temperature Control See Figure Bun Thickness AdjustmentOperation Operating Instructions see figure #4VSX-10 Temperature Control See Figure Status, Alarm, and Error Messages See FigureCleaning EN Español CleaningCleaning Instructions El Procedimiento de LimpiezaRelease Sheet Care and Replacement Problem Possible Cause Corrective Action Manual Reset Thermostat Preventative Maintenance Schedule Page Important for Future Reference Limit SW Wiring Diagrams2724 Parts List & Exploded ViewUsedOn Procedure for Conveyor Belt Tracking Page Opposite BakProcedure for Conveyor Belt Adjustment Tracking Conveyor Belt Adjustment