Extron electronic DMP128 installation instructions Digital I/O Wiring

Page 2
Tx Rx G

DMP 128 • Setup Guide (Continued)

F Digital I/O connectors — Connect up to four 6-pole 3.5 mm captive screw connectors. Each connector provides five configurable digital input or output ports allowing connection of up to twenty devices such as motion detectors, alarms, lights, LEDs, buttons, photo (light) sensors, and temperature sensors.

Digital I/O ports can monitor or drive TTL level digital signals. The inputs are configured to operate in one of two modes: digital input or digital output. In output mode, the device sources up to 250 mA at +5 V. In input mode, voltages greater than 1 V indicate a logic ‘high’ signal while voltages less than 1 V indicate a logic 'low'.

Digital I/O ports are tied to a common ground (one common ground for each 6-pole connector).

163 " (5 mm) MAX.

Do not tin the wires!

1

2

3

4

5

G

Digital I/O Wiring

G Connect a control system — There are three options to connect a control system to the DMP 128: LAN, RS232, and USB (front panel only). Extron recommends using the LAN port for configuration and remote control of the DMP 128.

RS-232— Connect the host RS-232 cable to the rear panel of the switcher (Å) using the provided 3-pole captive screw connector for bi-directional RS-232 (±5 V) serial control. The default baud rate is 38400. Use the wiring diagram at right.

LAN — Using a standard Ethernet cable, connect to a network via the LAN port (Ç). The table at right shows the default network settings. The control system and DMP 128 must be connected on the same network.

NOTE: To connect the DMP 128 directly to a computer Ethernet port, use a crossover Ethernet cable.

RS-232

Device

 

 

Bidirectional

Transmit (Tx)

 

 

Transmit (Tx)

Receive (Rx)

 

Receive (Rx)

Ground ( G )

 

Ground ( G )

 

 

 

 

 

IP Address:

192.168.254.254

 

 

Subnet Mask:

255.255.0.0

 

 

Default Gateway:

0.0.0.0

 

 

DHCP:

OFF

 

 

USB — Connect the host USB port to the front panel configuration port, (not shown), using a

USB A to mini-B cable. The USB connection is used only for configuration. Use the RS-232 or LAN port for remote control of the DMP 128.

H EXP port connector — One RJ-45 jack for digital audio connection to an additional DMP 128 using the Extron proprietary protocol. Use the included one foot long shielded CAT 6 cable to connect two DMP 128 units to form a larger matrix system. The expansion bus supports 16 bi-directional channels of audio; eight assignable channels that are mixed from any of the input and virtual paths, and eight channels directly connected to the virtual return path outputs. See the DMP 128 User Guide for operation details.

I Reset button and LED indicator — The reset button returns the DMP 128 to different tiers of default states and places the unit into an event recording mode for troubleshooting. The LED flashes to signify the different tiers (see “DMP 128 Hardware Reset Modes” in the DMP 128 User Guide).

J AT ports (AT models only) — Four RJ-45 jacks form a 4-port Gigabit switch that interfaces with the AT bus. The

AT expansion bus uses the Dante™ protocol for digital media networking allowing connection of multiple DMP 128 AT models to form a larger matrix. See the DMP 128 User Guide for operation details.

NOTE: The Dante Controller software is required for configuration of the AT expansion bus (see Dante Controller Software Installation (AT models only) on the next page).

K Telephone ports (P models only) — Two RJ-11 jacks for incoming line (LINE) and telephone (PHONE) connection.

The telephone interface follows all applicable US standards and international standards for select countries. A phone dialer is available in the DSP Configurator control software to assist with setup and testing.

When all connections have been made, power up the input and output devices, then apply power to the DMP 128.

2

Image 2
Contents Audio Output Wiring Disconnect Power and Mount the DMPAudio Input Wiring ConnectionsDigital I/O Wiring Dante Controller Software Installation AT models only DSP Configurator Software InstallationDMP 128 Configuration Dante Network Audio Setup Telephone Ports DMP 128 C P and DMP 128 C P AT only