Bunn IMIX -5S+A Programming the Dispenser NORMAL/PROGRAM/RINSE switch, Programming Lockout Switch

Page 10

PROGRAMMING THE DISPENSER (cont.)

NORMAL/PROGRAM/RINSE switch:

NORMAL: Allows all dispenser functions. Must be in this position for dis- pensing.

PROGRAM: Allows access to program menus using touch pad and LCD screen.

RINSE: Disables hopper motors. Pressing dispense button on front door will dispense dilution water and power whipper motor for ten seconds.

P3060

PROGRAMMING LOCKOUT SWITCH

This switch can be set to prevent access to the programming mode of the dispenser. Once all the correct settings are programmed, the operator can set the switch to the “ON” position to prohibit anyone from changing the settings.

P3060

PROGRAMMING CUP SIZES - Portion Control Models

The cup size can be programmed in portion control models by “EXAMPLE” or “TIME”. Programming by EX- AMPLE is manually pressing desired dispense button, then releasing when the desired cup size is attained. The time required to fill the cup will be stored in the controller memory when moving to the next menu. Program- ming by TIME is setting the actual dispense time in seconds for each cup size desired.

Place the “NORMAL/PROGRAM/RINSE” switch in the “PROGRAM” position. Press button A (page 8) below the BUNN logo on front of the door until the “SET CUP SIZE” menu is reached. (Refer to menu J, page 12) Press button D (page 8) to select programming by “EXAMPLE”. Place proper cup under dispense tip for station you desire to set. Press desired dispense button, then release when the cup is 3/4 full. If cup is not full enough, the dispense button can be pressed again to add additional beverage to the cup. If cup has reached desired level, press button B under “SAVE” to record the dispense time. If cup is overfilled, press button D under “REPEAT”. Empty cup and repeat the process.

If setting cup sizes by “TIME” is desired, press button B under “TIME” in the “SET CUP SIZE” menu. “HEAD 1 SM TIME” will be displayed, along with current time setting. Pressing either button D below (-) or button B below (+) will subtract or add time in .1 second increments. Each one second of time equals approximately 1.25 ounces of beverage at factory settings. When desired time is set, press button A to continue to next cup size.

When the desired cup sizes have been programmed, press button C to exit program menus, or press button A to move to the next menu. If button C was selected to exit the program mode, return the “NORMAL/PRO- GRAM/RINSE” switch to the “NORMAL” position to return to nomal operation.

10

38987 032306

Image 10
Contents IMIX-3S+ IMIX-3S+A IMIX-5S+ IMIX-5S+A BUNN-O-MATIC Commercial Product Warranty 28328.0011 User Notices00831.0000 37881.0000CE Requirements Initial SET-UPElectrical Requirements Plumbing Requirements Preset Tank TemperatureRinse Timer Plumbing HOOK-UPRunning a Rinse Sequence Door Graphic and Lens InstallationPreventive Maintenance Hopper Dispense Rate of ProductCleaning 24hGlossary Important Programming Notes Read Carefully Programming SwitchesProgramming the Dispenser Gram Home Screen Program Home ScreenProgramming the Dispenser NORMAL/PROGRAM/RINSE switch Programming Lockout SwitchProgramming the Dispenser Adjust hopper Motor speed for Station selected Returns to EStation Goes to next stationContinues after last Returns to G