ELECTRICAL REQUIREMENTS
The grinder has an attached cordset and requires
CE REQUIREMENTS
•This appliance must be installed in locations where it can be overseen by trained personnel.
•For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.
•Appliance shall not be tilted more than 10° for safe operation.
•An electrician must provide electrical service as specified in conformance with all local and national codes.
•This appliance must not be cleaned by water jet.
•This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of this appliance by a person responsible for its safety.
•Children should be supervised to ensure they do not play with the appliance.
• If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.
• Machine must not be immersed for cleaning. • Machine rated IPX1.
OPERATING CONTROLS
Off/On/Start Switch (Models LPGA and LPGA-2E)
OFF - (upper position) Switching to this position stops all operation of the grinder.
ON - (middle position) The switch will return to this position after a grind cycle has begun and will remain in this position after grinding has ceased. START - (lower, momentary position) Pressing the switch to this position and releasing initiates a grind cycle.
Hopper Selector Switch (Model LPGA-2E only)
LEFT - Switching to this position allows beans to be ground from the left hopper.
RIGHT - Switching to this position allows beans to be ground from the right hopper.
PREVENTIVE MAINTENANCE
P1028 |
P1029 |
NOTE: Replacement parts or service caused by failure to perform required maintenance is not covered by warranty.
Weekly Cleaning plus replace the dechaffer assembly.
1-Year
1.On grinders with slide plates check the slide plates and clean.
2.Inspect and clean/replace burrs and grind chamber if necessary.
3.Adjust the burrs and grind time to your specifications for particulate size and throw weight.
4 | 27091.1 042211 |
|