Extron electronic MTP R 15HD RSA D Installation and Operation, cont’d, Final installation

Page 9

Installation and Operation, cont’d

5. Secure the wall box with nails or screws, leaving the front edge flush with the outer wall or furniture surface. See figure 2-2.

Wall Stud

Wall Stud

Signal

Signal

Output

Output

Cable

Cable

 

Cable

Cable

Clamp

Clamp

Screws

Screws

or Nails

or Nails

 

10. Connect a video and an RS-232 and/or audio device to the front panel (see "Front panel features", later in this chapter, for connector details).

11. Restore the power supply, and test the transmitter/receiver system. Make any cabling adjustments before final installation, as the cables will be inaccessible afterwards.

Final installation

After testing and making any adjustments, do the following:

1. At the power outlet, unplug the power supply.

2. Mount the receiver into the box, and attach the supplied Decora faceplate to the unit, as shown in figure 2-3.

Figure 2-2 — Installing the wall box

NIf attaching the wall box to wood, use four #8 or #10 screws or 10-penny nails. A minimum of 0.5" (1.3 cm) of screw thread must penetrate the wood.

If attaching the wall box to metal studs or furniture, use four #8 or #10 self-tapping sheet metal screws or machine bolts with matching nuts.

6. Feed the power cable through the opening and through the wall box punch-out holes into the box, securing the cable

Wall Box

Wall opening is flush with edge of box.

Extron

MTP R 15HD RSA D

PEAK

LEVEL

-232 RS

AUDIO

Rx

Tx

OUTPUT

Decora

Faceplate

with cable clamps to provide strain relief.

NIn order to fit in the junction box, the TP cable and RJ-45 connector should not have a boot installed.

7. Feed the twisted pair cable pigtail out through the wall box punch-out holes, securing the pigtail with cable clamps to provide strain relief.

8. Trim back and/or insulate exposed cable shields with heat shrink to reduce the chance of short circuits.

To prevent short circuits, the outer foil shield can be cut back to the point where the cable exits the cable clamp.

9. Connect the power cable to the rear of the unit and the TP cable to the RJ-45 pigtail. See "Rear panel features", later in this chapter, for connector wiring details.

Figure 2-3 — Mounting the receiver

3. At the power outlet, reconnect the power supply.

2-4

MTP R 15HD RSA D • Installation and Operation

MTP R 15HD RSA D • Installation and Operation

2-5

Image 9
Contents MTP 15HD Decora Receiver MTP R 15HD RSA DExtron’s Warranty PrecautionsFCC Class a Notice 安全须知 中文Table of Contents One Table of Contents, cont’dAbout the MTP 15HD Decora Receiver IntroductionTwisted Pair TP Cable Advantages RS-232 functionIntroduction, cont’d Pre-Peak Max . distanceHigh quality Variable quality Installation InstallationUL/safety requirements Preparing the site and installing the wall boxInstallation and Operation, cont’d Final installationMTP R 15HD RSA D Installation and Operation Rear panel features Installation and Operation, cont’d Connections and SettingsFront panel features Power supply wiringMaking Connections TP cable termination TP cable termination Skew Delay Compensation Receiver ConsiderationsAudio/RS-232 cable termination AAppendix a Reference Information SpecificationsReference Information, cont’d MTP receiver and compatible transmitters and switchersPart Numbers Included partsConnectors Decora Template DimensionsConnector Part number CAT 6 jack black, qty 100-476-01 CablesReference Information, cont’d