Bunn TU3 Service Digital Brew Timer Late Models, If voltage is as described, proceed to #7

Page 18

SERVICE (cont.)

DIGITAL BREW TIMER (Late Models)

P2202.40

FIG. 6 DIGITAL BREW TIMER

Location:

The timer is located in the hood, on the left side.

Test Procedure:.

NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board.

1.Disconnect the brewer from the power source and remove the front access panel.

2.Remove the two #8-32 screws securing circuit board to the mounting bracket.

3.Remove circuit board and spacers (as required).

4.With a voltmeter, check the voltage across termi- nals TL1 and TL2 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be:

a)120 volts ac for two wire 120 volt models.

b)240 volts ac for two wire 240 volt models.

c)100 volts ac for two wire 100 volt models.

5.Disconnect the brewer from the power source.

If voltage is present as described, proceed to #6.

If voltage is not present as described, refer to the Wiring Diagrams and check the brewer wiring har- ness.

6.With a voltmeter, check the voltage across termi- nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source. The indication must be 0 volts.

If voltage is as described, proceed to #7.

If voltage is not as described, disconnect the brewer from the power source and replace the timer.

7.With a voltmeter, check the voltage across termi- nals TL1 and TL4 when the "ON/OFF" switch is in the "ON" position. Connect the brewer to the power source and press the "START" switch. The indica- tion must be as follows:

a)120 volts ac for two wire 120 volt models.

b)240 volts ac for two wire 240 volt models.

c)100 volts ac for two wire 100 volt models.

If voltage is present as described, the brew timer is operating properly. Reset the timer as required, to obtain the desired brew volume.

If voltage is not present as described, disconnect the brewer from the power source and replace the timer.

Removal and Replacement:

1.Remove the two #8-32 screws securing circuit board to the hood.

2.Remove circuit board and spacers (as required).

3.Remove all wires from the timer.

4.Attach all wires to the replacement timer board prior to installation to the component mounting bracket. Refer to FIG. 7 when reconnecting the wires.

5.Install new circuit board with spacers (as re- quired) to the component mounting bracket.

6.Adjust the timer as described below.

Timer Setting:

NOTE: Prior to setting or modifying volumes, check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server are in place. NOTE: All volume settings must be done with the sprayhead installed.

1.Modifying brew volumes. To modify a brew vol- ume, first check that the SET/LOCK switch is in the "SET" position on the circuit board.

Page 18

10225

071500

 

 

Image 18
Contents TU3 Phone 217 529-6601 FAX 217Contents BUNN-O-MATIC Commercial Product WarrantyIntroduction User Notices #00831.0000 #00656.0000#03408.0002 #03409.0002 #03408.0000 #03409.0000 Electrical Requirements Plumbing RequirementsElectrical Hook-Up Initial SET-UP StoppedAdjusting Brew Volumes Auto Sweetener SET-UPInitial SET-UP Cleaning Operating ControlsAuto Sweetener Cleaning CleaningTEA Brewing Troubleshooting Problem Probable CauseRemedy Troubleshooting ProblemRemedy Problem Probable Cause Remedy Dilution cycle will not start Dilution Solenoid ValveFunnel Tip Spitting or excessive steamingDrip-out time too long Control Thermostat Ticles clogging the drip-out tipBeverage overflows dispenser Dispenser See Dilution TimerIng Water Temperature Dilution Solenoid ValveRemove and clean lime off the tank heater. See Dry tea leaves remain in the funnel Service Component Access Contents Service Brew Solenoid ValveSolenoid valve Service Brew Timer Early Models Brew TimerService Digital Brew Timer Late Models If voltage is as described, proceed to #7Digital Timer Wiring Control Thermostat Dilution Solenoid Valve Dilution Solenoid ValveDilution Timer Limit Thermostat Indication must beIng Diagrams and check the wiring harness ON/OFF SwitchON/OFF Switch Selector Switch Optionalcont Start Switch Start SwitchSweetener Solenoid Valve Optional Tank Heater 10225 071500 10225 071500 Single Phase Volts AC10225 071500