Carrier manual Physical data, 23XRV Compressor and Motor Weights, Component Weights

Page 5

Physical data

23XRV COMPRESSOR AND MOTOR WEIGHTS

 

 

ENGLISH

 

 

 

SI

 

 

MOTOR

Total

Stator

Rotor

Motor

Compressor

Stator

Rotor

Motor

Compressor

Terminal

Terminal

SIZE

Weight

Weight

Weight

Weight

Weight

Weight

Cover

Cover

 

(lb)

(lb)

(kg)

(kg)

(kg)

 

(lb)

(lb)

(kg)

 

 

 

 

 

 

P,Q,R,S,

4866

441

229

46

2207

200

104

21

T,U,V

 

 

 

 

 

 

 

 

COMPONENT WEIGHTS

 

FRAME 3 HEAT

FRAME 4 HEAT

FRAME 5 HEAT

COMPONENT

EXCHANGER

EXCHANGER

EXCHANGER

 

lb

kg

lb

kg

lb

kg

Isolation Valves

70

32

70

32

115

52

Suction Elbow

179

81

237

108

232

105

Discharge Elbow/Muffler

747

339

747

339

747

339

Control Center/VFD

1650

749

1650

749

1650

749

Vaporizer and Oil Sump

700

318

700

318

700

318

Economizer

542

246

542

246

542

246

LEGEND

 

 

 

 

 

 

VFD — Variable Frequency Drive

 

 

 

 

 

 

23XRV HEAT EXCHANGER WEIGHTS

 

 

 

 

 

ENGLISH

 

 

 

 

METRIC (SI)

 

 

 

 

 

Dry Rigging

 

 

 

 

Dry Rigging

 

 

 

 

 

NUMBER

Weight

 

Machine Charge

 

Weight

 

Machine Charge

 

CODE

OF TUBES

(lb)*

 

 

 

 

(kg)*

 

 

 

 

 

 

 

 

Refrigerant

Liquid Weight

 

 

Refrigerant

Liquid Weight

 

 

 

 

 

 

 

 

 

 

Cooler

Cond.

Weight (lb)

(lb)

Cooler

Cond.

Weight (kg)

(kg)

 

Cooler

Cond.

Only

Only

With

Without

Cooler

Cond.

Only

Only

With

Without

Cooler

Cond.

 

 

 

Economizer

Economizer

 

 

Economizer

Economizer

30

200

218

4148

3617

800

650

464

464

1877

1676

363

295

210

210

31

240

266

4330

3818

800

650

531

542

1959

1769

363

295

241

246

32

282

315

4522

4023

800

650

601

621

2046

1860

363

295

273

282

35

200

218

4419

4529

910

760

511

513

2000

2089

413

345

232

233

36

240

266

4627

4758

910

760

587

602

2094

2195

413

345

266

274

37

282

315

4845

4992

910

760

667

692

2193

2299

413

345

303

314

40

324

366

5008

4962

900

825

863

915

2675

2746

408

375

391

415

41

364

415

5178

5155

900

825

930

995

2758

2839

408

375

422

451

42

400

464

5326

5347

900

825

990

1074

2832

2932

408

375

449

487

45

324

366

5463

5525

1015

960

938

998

2882

3001

460

436

425

453

46

364

415

5659

5747

1015

960

1014

1088

2976

3108

460

436

460

494

47

400

464

5830

5967

1015

960

1083

1179

3061

3214

460

436

491

535

50

431

507

5827

6013

1250

1100

1101

1225

3182

3304

567

499

499

556

51

485

556

6053

6206

1250

1100

1192

1304

3294

3397

567

499

541

591

52

519

602

6196

6387

1250

1100

1248

1379

3364

3485

567

499

566

626

55

431

507

6370

6708

1430

1280

1201

1339

3429

3620

649

581

545

607

56

485

556

6631

6930

1430

1280

1304

1429

3556

3726

649

581

591

648

57

519

602

6795

7138

1430

1280

1369

1514

3636

3826

649

581

621

687

COND — Condenser

*Rigging weights are for standard tubes of standard wall thickness (EDE and Spikefin 3, 0.025-in. [0.635 mm] wall).

NOTES:

1.Cooler includes the suction elbow and 1/2 the distribution piping weight.

2.Condenser includes float valve and sump, discharge elbow, and 1/2 the distribution piping weight.

3.For special tubes, refer to the 23XRV Computer Selection Program.

4.All weights for standard 2-pass NIH (nozzle-in-head) design with vic- taulic grooves.

5

Image 5
Contents 23XRV Features/BenefitsProduct reliability Table of contents Microprocessor controls features Heat exchanger featuresA23-1648 Model number nomenclatureComponent Weights 23XRV Compressor and Motor Weights23XRV Heat Exchanger Weights Physical dataNumber Additional Weights for 23XRV Marine WaterboxesFrame PassesOption ACCESSORY† → Options and accessories23XRV Dimensions Dimensions23XRV Dimensions NOZZLE-IN-HEAD Waterbox 23XRV Dimensions Marine WaterboxNozzle Size Performance data23XRV Heat Exchanger MIN/MAX Flow Rates Cooler PassAuxiliary Ratings Electrical dataVFD Frame Sizes Controls FeaturesMicroprocessor controls Control systemControl Panel Display Front View CCM CCN Communication Wiring for Multiple Chillers TypicalControl Sequence Control sequence23XRV Chiller Typical piping and wiringGND Ground Control wiring schematic23XRV Component Arrangement Application data Dimensions mm→ 23XRV Machine Footprint 23XRVA23-1647 23XRV Isolation with Accessory Soleplate PackageCooler Waterboxes 23XRV Nozzle ArrangementsCondenser Waterboxes Out23XRV Nozzle Arrangements Relief Valve Arrangements Relief Valve LocationsRelief valve discharge pipe sizing Vent and drain connectionsAsme stamping Design pressures23XRV Minimum FIELD-INSTALLED Insulation Requirements → Minimum fluid loop volumeInsulation Condensation VS Relative HumidityHvac Guide Specifications Guide specificationsWarranty Guide specifications Page Guide specifications Page Guide specifications Page Carrier Corporation Syracuse, New York 910

23XRV specifications

The Carrier 23XRV is a high-performance commercial rooftop unit designed for versatility and efficiency in various applications. As part of Carrier's commitment to providing superior HVAC solutions, the 23XRV combines advanced technologies with robust construction to meet the demands of modern commercial environments.

One of the standout features of the 23XRV is its superior energy efficiency. The unit is equipped with a variable speed compressor that adjusts the cooling output based on real-time demand. This allows for optimal efficiency even during partial load conditions, significantly reducing energy consumption and operational costs. It boasts a high SEER (Seasonal Energy Efficiency Ratio) and EER (Energy Efficiency Ratio) ratings, making it an environmentally friendly option that helps to lower carbon footprints.

The 23XRV is constructed with a strong focus on durability. Its robust frame and high-quality materials ensure resilience against harsh weather conditions and extend the unit's service life. The design also incorporates sound-attenuating features, minimizing operational noise and making it suitable for noise-sensitive environments like schools and hospitals.

In terms of technology, the Carrier 23XRV utilizes advanced microprocessor controls that enable precise temperature management and system diagnostics. This smart control system provides enhanced functionality, allowing for easy monitoring and configuration through a user-friendly interface. Additionally, the unit is compatible with remote monitoring systems, enabling building managers to track performance and make adjustments as necessary from any location.

The refrigerant used in the 23XRV is R-410A, which is chlorine-free and meets stringent environmental regulations. The choice of refrigerant not only enhances the efficiency of the system but also aligns with global efforts to phase out ozone-depleting substances.

Maintenance and serviceability are also key considerations in the design of the 23XRV. Features such as easy access to components for routine maintenance, modular construction for quicker repairs, and extensive diagnostic capabilities reduce downtime and enhance overall reliability.

Overall, the Carrier 23XRV stands out in the commercial HVAC market with its combination of efficiency, durability, and advanced technology. It is an excellent choice for various commercial applications, providing reliable performance and improved energy management for building owners and operators looking to enhance their HVAC systems.