Carrier 23XRV manual Model number nomenclature, A23-1648

Page 4

Features/Benefits (cont)

feature also allows the machine to operate at reduced capacity, rather than shut down, when key safety limits are approached.

Chilled liquid reset — Reset can be accomplished manually or automatical- ly from the building management sys- tem. For a given capacity, reset allows operation at slower compressor speeds, saving energy when warmer chilled liquid can be used.

Demand limiting — This feature lim- its the power draw of the chiller during peak loading conditions. When incor- porated into the Carrier Comfort Network® building automation system, a red line command holds chillers at their present capacity and prevents any other chillers from starting. If a load shed signal is received, the compres- sors are unloaded to avoid demand charges whenever possible.

Ramp loading — Ramp loading en- sures smooth pulldown of liquid loop temperature and prevents a rapid increase in compressor power con- sumption during the pulldown period.

Automated controls test — The test can be executed prior to start-up to verify that the entire control system is functioning properly.

365-day real time clock — This feature allows the operator to program a yearly schedule for each week, week- ends, and holidays.

Occupancy schedules — Schedules can be programmed into the controller to ensure that the chiller operates when cooling is required and remains off when not needed by the tenants or process.

Extensive service menu — Unau- thorized access to the service menu

can be prevented through password protection. Built-in diagnostic capabili- ties assist in troubleshooting and rec- ommend proper corrective action for preset alarms, resulting in greater working time.

Alarm file — This file maintains the last 25 time-and date-stamped alarm messages in memory. This function re- duces troubleshooting time and cost.

Alert file — This file maintains the last 25 alert messages in memory. This function provides prognostic informa- tion and corrective actions that can avoid unit shutdown.

Configuration data backup — Non-volatile memory provides protection during power failures and eliminates time consuming control reconfiguration.

Model number nomenclature

23XRV – High Efficiency

Variable Speed Screw Chiller

Cooler Size* 30-32 35-37 40-42 45-47 50-52 55-57

Condenser Size* 30-32 35-37 40-42 45-47 50-52 55-57

Economizer Option

E – With Economizer

N – No Economizer

R – Compressor

S– Special

Not Used

Voltage Code

3380-3-60

4416-3-60

5460-3-60

9380/415-3-50

Drive

Amps

Amps

Code

In†

Out†

AA

440

442

BA

520

442

BB

520

520

CC

608

608

Motor Code

 

P

T

a23-1648

Q

U

RV

S

*First number denotes frame size.

†Maximum limits only. Additional application limits apply that may reduce these ampacities.

Quality Assurance

Certified to ISO 9001:2000

ASME

AHRI (Air Conditioning, Heating

‘U’ Stamp

and Refrigeration Institute)

 

Performance Certified

SEISMICOMPLIANT*

* Meets IBC 2006, ASCE-7-05, CBC 2007, and OSHPD seismic requirements.

4

Image 4
Contents Product reliability Features/Benefits23XRV Table of contents Heat exchanger features Microprocessor controls featuresModel number nomenclature A23-164823XRV Compressor and Motor Weights Component Weights23XRV Heat Exchanger Weights Physical dataAdditional Weights for 23XRV Marine Waterboxes NumberFrame Passes→ Options and accessories Option ACCESSORY†Dimensions 23XRV Dimensions23XRV Dimensions NOZZLE-IN-HEAD Waterbox 23XRV Dimensions Marine WaterboxPerformance data Nozzle Size23XRV Heat Exchanger MIN/MAX Flow Rates Cooler PassVFD Frame Sizes Electrical dataAuxiliary Ratings Features ControlsMicroprocessor controls Control systemControl Panel Display Front View CCN Communication Wiring for Multiple Chillers Typical CCMControl sequence Control SequenceTypical piping and wiring 23XRV Chiller23XRV Component Arrangement Control wiring schematicGND Ground Dimensions mm Application data→ 23XRV Machine Footprint 23XRV23XRV Isolation with Accessory Soleplate Package A23-164723XRV Nozzle Arrangements Cooler WaterboxesCondenser Waterboxes Out23XRV Nozzle Arrangements Relief Valve Locations Relief Valve ArrangementsVent and drain connections Relief valve discharge pipe sizingAsme stamping Design pressures→ Minimum fluid loop volume 23XRV Minimum FIELD-INSTALLED Insulation RequirementsInsulation Condensation VS Relative HumidityGuide specifications Hvac Guide SpecificationsWarranty Guide specifications Page Guide specifications Page Guide specifications Page Carrier Corporation Syracuse, New York 910

23XRV specifications

The Carrier 23XRV is a high-performance commercial rooftop unit designed for versatility and efficiency in various applications. As part of Carrier's commitment to providing superior HVAC solutions, the 23XRV combines advanced technologies with robust construction to meet the demands of modern commercial environments.

One of the standout features of the 23XRV is its superior energy efficiency. The unit is equipped with a variable speed compressor that adjusts the cooling output based on real-time demand. This allows for optimal efficiency even during partial load conditions, significantly reducing energy consumption and operational costs. It boasts a high SEER (Seasonal Energy Efficiency Ratio) and EER (Energy Efficiency Ratio) ratings, making it an environmentally friendly option that helps to lower carbon footprints.

The 23XRV is constructed with a strong focus on durability. Its robust frame and high-quality materials ensure resilience against harsh weather conditions and extend the unit's service life. The design also incorporates sound-attenuating features, minimizing operational noise and making it suitable for noise-sensitive environments like schools and hospitals.

In terms of technology, the Carrier 23XRV utilizes advanced microprocessor controls that enable precise temperature management and system diagnostics. This smart control system provides enhanced functionality, allowing for easy monitoring and configuration through a user-friendly interface. Additionally, the unit is compatible with remote monitoring systems, enabling building managers to track performance and make adjustments as necessary from any location.

The refrigerant used in the 23XRV is R-410A, which is chlorine-free and meets stringent environmental regulations. The choice of refrigerant not only enhances the efficiency of the system but also aligns with global efforts to phase out ozone-depleting substances.

Maintenance and serviceability are also key considerations in the design of the 23XRV. Features such as easy access to components for routine maintenance, modular construction for quicker repairs, and extensive diagnostic capabilities reduce downtime and enhance overall reliability.

Overall, the Carrier 23XRV stands out in the commercial HVAC market with its combination of efficiency, durability, and advanced technology. It is an excellent choice for various commercial applications, providing reliable performance and improved energy management for building owners and operators looking to enhance their HVAC systems.