Extron electronic XTRA SERIES manual UL Requirements

Page 13

The optional Flexible Conduit Adapter Kit consists of:

One EMT adapter plate

One 6-foot long electrical conduit

Three 7.5 feet, 18-gauge spade connector power wires

One UL-rated zip tie wrap

Three auxiliary crimp style spade connectors designed for 14- to 16-gauge wires

NOTE: If needed, Extron recommends using a UL-rated crimp tool to terminate the spade connectors. One recommended choice is the Molex crimp tool.

The kit provides a convenient means to replace the IEC power cord of the XPA with conduit, where required by local codes.

UL Requirements

The UL requirements listed below pertain to the installation of the flexible conduit onto a XPA 1002 or XPA 2001.

This unit is not to be used beyond its rated voltage range.

This unit must be wired to a UL listed distribution box.

NOTE: The UL approved electrical distribution box is not included with either the XPA or the Flexible Conduit Adapter Kit. The installer is responsible for obtaining and installing the box.

Installing the Flexible Conduit Kit

ATTENTION: Electrostatic discharge (ESD) can damage IC chips even though you cannot feel it. You must be electrically grounded before touching anything inside the XPA. A grounding wrist strap is recommended.

Install flexible conduit to the XPA by following the steps below.

1.Unplug the IEC power cord from the power amplifier.

2.Remove the 8 screws from the top and sides of the XPA and lift off the cover (see figure 5).

Lift Cover Straight Up

Remove (8) screws

-60Hz 50 0.5A,

-240V 100

1002 XPA

LIMITER/PROTECTSIGNAL

2 1

ATTENUATION

 

 

2

1

 

10 8

 

12

10 8

6 14

 

12

4

0

14

2

180

26

6 4

2

INPUTS2 1

 

REMOTE

 

 

50mA

10V

 

G

 

C

G

V

 

STANDBY

 

/ 4Ω

OUTPUTS

2

1

 

 

 

 

 

2

CLASS

 

Figure 5. Removing the Cover

XTRA Series Half-Rack Audio Power Amplifiers • Installation

7

Image 13
Contents User Guide Safety Instructions Conventions Used in this Guide FCC Class B NoticeNotifications Page Contents Page Continuous power output for larger rooms FeaturesAbout this Manual Terms Used in this ManualXtra Series Half-Rack Audio Power Amplifiers Introduction XPA 1002 Series Application Example Application ExamplesTabletop Use Mounting the Xtra Series AmplifiersUL Guidelines for Rack Mounting Rack Mounting of the Amplifier Rack MountingAllow Sufficient Spacing for Adequate Ventilation Flexible Conduit Adapter Kit InstallationUL Requirements Removing the IEC Connector Power indicator LED This LED lights Front Panel Features and OperationLIMITER/PROTECT XPA XPA 1002 Plus Rear Panel Rear Panel Features and OperationBalanced or unbalanced stereo or mono audio input connector Inputs 3 4 XPA XPA 1002 Plus XPA Remote Volume Control Controlling Multiple Amplifiers with One Volume Controller Bridging the Output of the XPA 1002 Series Bridged Mono OutputAmplifier Fails to Exit Standby Mode Promptly TroubleshootingLimiter/Protect LED Warning Indicators Amplifier Enters Standby Mode Too EarlyOver Temp Indicator LED LED State Problem Description Problem SolutionEurope and Africa China USA, Canada, South America Central America JapanAsia Middle East Europe
Related manuals
Manual 23 pages 191 b

XTRA SERIES specifications

The Extron XTRA Series is designed to redefine performance in the realm of AV system control and signal processing. This extensive lineup comprises high-quality products that cater to the demands of modern AV environments, ensuring seamless integration and exceptional functionality.

One of the hallmark features of the XTRA Series is its advanced signal routing capabilities. With support for a variety of audio and video formats, including HDMI, HDBaseT, and analog signals, users can easily manage and distribute content across multiple displays and zones. This versatility is crucial for settings such as educational institutions, corporate environments, and large venues where different types of media are routinely used.

A standout characteristic of the XTRA Series is its robust control capabilities. The series incorporates Extron's signature GlobalViewer Enterprise software, enabling users to monitor and manage AV devices remotely. This feature not only simplifies system administration but also enhances troubleshooting efficiency, allowing technicians to quickly identify and resolve issues without needing to be physically present.

In terms of technology, the XTRA Series is built on Extron's advanced DSP (Digital Signal Processing) platform. This ensures superior audio quality, with features like automatic gain control, equalization, and feedback suppression, which are essential for delivering clear and articulate sound in any environment. Additionally, the series includes built-in video scaling and switching technologies, allowing for high-resolution output that maintains the integrity of the original media.

Another important aspect of the XTRA Series is its user-friendly interface. Many products in this lineup are designed with customizable touch panels and intuitive control systems that can be tailored to meet the specific needs of various users. This adaptability makes it easy for anyone, regardless of technical expertise, to operate and manage AV systems effectively.

The XTRA Series is also designed with reliability in mind. With durable construction and rigorous testing processes, these products are built to perform consistently in high-demand environments. This reliability is further complemented by Extron's dedicated customer support, providing users with the assistance and resources needed to maximize their system's capabilities.

Overall, the Extron XTRA Series stands as a testament to innovation in AV technology, combining sophisticated signal processing, intuitive control, and exceptional reliability to provide comprehensive solutions for a wide array of applications. Whether for corporate environments, educational facilities, or large-scale events, the XTRA Series ensures that users enjoy a seamless and enriched audio-visual experience.