Agilent Technologies E4403B, E4411B, E4408B Align Now All has been run When Align Now All is run

Page 74

E4411B Specifications and

Characteristics

Agilent

 

Agilent E4411B Specifications and Characteristics

About This Chapter

About This Chapter

This chapter contains specifications and characteristics for the Agilent E4411B spectrum analyzer. The distinction between specifications and characteristics is described as follows.

Specifications describe the performance of parameters covered by the product warranty. (The temperature range is 0 ° C to 55 ° C, unless otherwise noted.)

Characteristics describe product performance that is useful in the application of the product, but is not covered by the product warranty.

Typical performance describes additional product performance information that is not covered by the product warranty. It is

performance beyond specification that 80% of the units exhibit with a 95% confidence level over the temperature range 20 to 30 ° C. Typical performance does not include measurement uncertainty.

Nominal values indicate the expected performance, or describe product performance that is useful in the application of the product, but is not covered by the product warranty.

The following conditions must be met for the analyzer to meet its specifications.

oThe analyzer is within the one year calibration cycle.

oIf Auto Align All is selected:

After 2 hours of storage within the operating temperature range.

5 minutes after the analyzer is turned on with sweep times less than 4 seconds.

oIf Auto Align Off is selected:

When the analyzer is at a constant temperature, within the operating temperature range, for a minimum of 90 minutes.

After the analyzer is turned on for a minimum of 90 minutes and

Align Now All has been run.

When Align Now All is run:

Every hour

If the ambient temperature changes more than 3 ° C

If the 10 MHz reference changes

74

Chapter 3

Image 74
Contents Specifications Guide Page Limitation of Warranty Where to Find the Latest Information Contents Contents Agilent E4403B Specifications About This Chapter Chapter Specifications Supplemental Information Frequency Range Specifications Supplemental Information Frequency ReferenceSpecifications Supplemental Information Frequency Span Specifications Supplemental Information Sweep TimeSpecifications Supplemental Information Sweep trace Points Option 1DRSpecifications Supplemental Information Video Bandwidth VBW Specifications Supplemental Information StabilityFrequency Specifications Supplemental Information Measurement Range Specifications Supplemental Information DB Gain CompressionHz Option 1DR Specifications Supplemental Information Display RangeTypical Specifications Supplemental Information Frequency Responsea Frequency Range Attenuation Dc-3.0 GHz Overall Amplitude AccuracybSpecifications Supplemental Information Auto Alignmenta Specifications Supplemental Information Reference Level RBW ≤ 300 Hz Option 1DR Specifications Supplemental Information Spurious Responses Specified Dynamic Range Specifications Supplemental Information Output Power Level Specifications Supplemental Information Warm-upSpecifications Supplemental Information Specifications Supplemental Information Spurious Outputs Specifications Supplemental Information Output Power SweepSpecifications Supplemental Information Output Flatness Specifications Supplemental Information Output Vswr ± 0.5 dB, characteristic Specifications Supplemental Information Immunity Testing Specifications Supplemental Information Temperature RangeSpecifications Supplemental Information EMI Compatibility Specifications Supplemental Information Power Requirements Specifications Supplemental Information Measurement SpeedSpecifications Supplemental Information Data Storage OptionSpecifications Supplemental Information Displaya DimensionsConnector Type-N female Impedance 50 Ω , nominal Specifications Supplemental Information Amptd REF OUTaSpecifications Supplemental Information Headphone Specifications Supplemental Information EXT KEYBOARDaSpecifications Supplemental Information Speaker Specifications Supplemental Information MHz REF OUTSpecifications Supplemental Information MHz REF Gate TRIG/EXT TrigInputs and Outputs Option A4H or 1AX Option 1AX Connector Pin D-SUB male RS-232Specifications Supplemental Information Parallel Interface Regulatory Information Declaration of Conformity Characteristics Agilent E4408B Specifications and Characteristics Agilent E4408B Specifications and Characteristics ± 2 × Specifications Supplemental Information Frequency Span Option 1DN MHz -3 dB RBW 30% KHz, 120 kHz -6 dB RBW 20% ≥ 1 kHz Option 1DR Frequency Amplitude Specifications Supplemental Information Display Range Specifications Supplemental Information Frequency Response Specifications Supplemental Information Amplitude Specifications Supplemental Information Auto Alignmenta Specifications Supplemental Information Reference Level RBW ≤ 300 Hz Option 1DR Specifications Supplemental Information Spurious Responses KHz to 6.7 GHz − 90 dBm KHz Not usable with resolution Bandwidths ≤ 300 Hz Specifications Supplemental Information Maximum Safe Reverse Specifications Supplemental Information Output Vswr Tracking Generator Output Accuracy Operating To 55 C Floppy disk 10 to 40 C Storage 40 to 75 C Option A4H Specifications Supplemental Information Memory Usage Option A4JSpecifications Supplemental Information Displaya Option BAB Rear Panel Gate TRIG/EXT Trig AUX if OUT Option A4JPresel Tune Output Regulatory Information Declaration of Conformity Agilent E4411B Specifications Align Now All has been run When Align Now All is run Every hour If the ambient temperature changes more than 3 C Option 1DP Option 1DN or 1DQ RBW − 79 dBc/Hz, typical Frequency 75 Ω Option 1DP Option 1DP nominal may75 Ω, Option 1DP KHz To − DB from ref level 04 dB Specifications Supplemental Information Frequency Responsea Agilent E4411B Specifications and Characteristics Specifications Supplemental Information Auto Alignment a Specifications Supplemental Information Reference Level RBW ≤ 300 Hz Option 1DR Specifications Supplemental Information Spurious Responses Specifications Supplemental Information Terminated and 0 dB Attenuation 50 Ω KHz to 1.5 GHz − 90 dBm Tracking Generator Option 1DN or 1DQ Option 1DQOption 1DNa 50 Ω Option 1DN75 Ω Option 1DQ Option 1DQaReferenced to 50 MHz, 0 dB Attenuator Specifications Supplemental Information Output Attenuator Tracking Generator Output Accuracy 50 Ω Option 1DNTracking Generator Output Accuracy 75 Ω Option 1DQ General Option A4H Option A4J 100 Connector BNC female Impedance 75 Ω Nominal Specifications Supplemental Information Amptd Ref aConnector Type-N female Impedance 50 Ω Nominal 102 Chapter 103 104 Option A4H Specifications Supplemental Information Gpib InterfaceSpecifications Supplemental Information Serial Interface Option 1AX106 Chapter 107

E4403B, E4411B, E4408B specifications

Agilent Technologies, a leader in electronic measurement solutions, has developed a range of instruments that revolutionize the way engineers and scientists perform RF and microwave analysis. Among these, the E4408B, E4411B, and E4403B stand out as highly versatile and powerful tools suited for various applications ranging from telecommunications to aerospace.

The Agilent E4408B is a high-performance spectrum analyzer that boasts a frequency range from 3 Hz to 26.5 GHz, making it suitable for a wide array of RF measurements. Its key features include a high dynamic range and a low phase noise, which considerably enhance measurement accuracy. The E4408B incorporates advanced digital signal processing technology, enabling real-time analysis of signals with remarkable precision. With its large touchscreen interface, users can easily navigate complex measurements and visualize data in an intuitive manner.

Another significant instrument is the E4411B, a versatile power meter that excels in measuring various types of RF power. Capable of measuring both average and peak power, the E4411B offers a frequency range from 9 kHz to 6 GHz. This power meter is particularly valued for its high-speed measurement capabilities and high accuracy, supporting a wide range of application scenarios such as wireless communications and broadcasting. Its built-in memory and connectivity options allow users to log and analyze data efficiently, enhancing the overall workflow.

The Agilent E4403B is a signal analyzer that supports a frequency range from 9 kHz to 3 GHz. This instrument is primarily designed for the analysis of communication signals, and it features a frequency domain analysis capability that makes it indispensable for modern communication systems. With its intuitive user interface, the E4403B facilitates quick access to vital measurements, reducing measurement times significantly. The analyzer’s excellent IP3 (third-order intercept point) specifications ensure reliable signal integrity, essential for ensuring robust communications.

In summary, Agilent Technologies' E4408B, E4411B, and E4403B represent a strong suite of measurement tools equipped with advanced technologies and features. They provide engineers with the capabilities needed to perform precise RF and microwave measurements across various industries, making them invaluable assets in the development and testing of modern electronic systems. With their user-friendly interfaces and high-performance specifications, these analyzers contribute significantly to innovation in technology and communication.