Agilent Technologies E4411B, E4408B Specifications Supplemental Information Reference Level

Page 87

Agilent E4411B Specifications and Characteristics

Amplitude

 

Specifications

Supplemental Information

 

 

 

Reference Level

 

 

Range

–149.9 dBm to maximum

 

 

mixer level + attenuator

 

 

setting

 

Resolution

 

 

Log Scale

± 0.1 dB

 

Linear Scale

± 0.12% of Reference Level

 

50 , Accuracy

 

 

(at a fixed frequency, a fixed

 

 

attenuator, and referenced to

 

 

35 dBm)

 

 

Reference Level (dBm) – input

 

 

attenuator setting (dB)

 

 

–10 dBm to > –60 dBm

± 0.3 dB

 

–60 dBm to > –85 dBm

± 0.5 dB

 

–85 dBm to –90 dBm

± 0.7 dB

 

75 (Option 1DP), Accuracy

 

 

(at a fixed frequency, a fixed

 

 

attenuator, and referenced to

 

 

18.75 dBmV)

 

 

Reference Level (dBmV) –

 

 

input attenuator setting (dB)

 

 

38.75 dBmV to

± 0.3 dB

 

> –11.25 dBmV

 

 

–11.25 dBmV to

± 0.5 dB

 

> –26.25 dBmV

 

 

–26.25 dBmV to

± 0.7 dB

 

–41.25 dBmV

 

 

 

 

 

 

Specifications

Supplemental Information

 

 

 

Display Scale Switching

 

 

Uncertainty

 

 

Switching between

± 0.15 dB at reference level

 

Linear and Log

 

 

Log Scale Switching

No error

 

 

 

 

Characteristics

Agilent E4411B Specifications

 

and

Chapter 3

87

Image 87
Contents Specifications Guide Page Limitation of Warranty Where to Find the Latest Information Contents Contents Agilent E4403B Specifications About This Chapter Chapter Specifications Supplemental Information Frequency Reference Specifications Supplemental Information Frequency RangeSpecifications Supplemental Information Sweep Time Specifications Supplemental Information Frequency SpanOption 1DR Specifications Supplemental Information Sweep trace PointsSpecifications Supplemental Information Stability Specifications Supplemental Information Video Bandwidth VBWFrequency Specifications Supplemental Information DB Gain Compression Specifications Supplemental Information Measurement RangeSpecifications Supplemental Information Display Range TypicalHz Option 1DR Specifications Supplemental Information Frequency Responsea Overall Amplitude Accuracyb Frequency Range Attenuation Dc-3.0 GHzSpecifications Supplemental Information Auto Alignmenta Specifications Supplemental Information Reference Level RBW ≤ 300 Hz Option 1DR Specifications Supplemental Information Spurious Responses Specified Dynamic Range Specifications Supplemental Information Warm-up Specifications Supplemental InformationSpecifications Supplemental Information Output Power Level Specifications Supplemental Information Output Power Sweep Specifications Supplemental Information Output FlatnessSpecifications Supplemental Information Spurious Outputs Specifications Supplemental Information Output Vswr ± 0.5 dB, characteristic Specifications Supplemental Information Temperature Range Specifications Supplemental Information EMI CompatibilitySpecifications Supplemental Information Immunity Testing Specifications Supplemental Information Measurement Speed Specifications Supplemental Information Power RequirementsOption Specifications Supplemental Information Data StorageDimensions Specifications Supplemental Information DisplayaSpecifications Supplemental Information Amptd REF OUTa Connector Type-N female Impedance 50 Ω , nominalSpecifications Supplemental Information MHz REF OUT Specifications Supplemental Information EXT KEYBOARDaSpecifications Supplemental Information Speaker Specifications Supplemental Information HeadphoneGate TRIG/EXT Trig Specifications Supplemental Information MHz REFInputs and Outputs Option 1AX Connector Pin D-SUB male RS-232 Specifications Supplemental Information Parallel InterfaceOption A4H or 1AX Regulatory Information Declaration of Conformity Characteristics Agilent E4408B Specifications and Characteristics Agilent E4408B Specifications and Characteristics ± 2 × Specifications Supplemental Information Frequency Span Option 1DN MHz -3 dB RBW 30% KHz, 120 kHz -6 dB RBW 20% ≥ 1 kHz Option 1DR Frequency Amplitude Specifications Supplemental Information Display Range Specifications Supplemental Information Frequency Response Specifications Supplemental Information Amplitude Specifications Supplemental Information Auto Alignmenta Specifications Supplemental Information Reference Level RBW ≤ 300 Hz Option 1DR Specifications Supplemental Information Spurious Responses KHz to 6.7 GHz − 90 dBm KHz Not usable with resolution Bandwidths ≤ 300 Hz Specifications Supplemental Information Maximum Safe Reverse Specifications Supplemental Information Output Vswr Tracking Generator Output Accuracy Operating To 55 C Floppy disk 10 to 40 C Storage 40 to 75 C Option A4H Option A4J Specifications Supplemental Information Memory UsageSpecifications Supplemental Information Displaya Option BAB Rear Panel Gate TRIG/EXT Trig Option A4J AUX if OUTPresel Tune Output Regulatory Information Declaration of Conformity Agilent E4411B Specifications Align Now All has been run When Align Now All is run Every hour If the ambient temperature changes more than 3 C Option 1DP Option 1DN or 1DQ RBW − 79 dBc/Hz, typical Frequency Option 1DP nominal may 75 Ω Option 1DP75 Ω, Option 1DP KHz To − DB from ref level 04 dB Specifications Supplemental Information Frequency Responsea Agilent E4411B Specifications and Characteristics Specifications Supplemental Information Auto Alignment a Specifications Supplemental Information Reference Level RBW ≤ 300 Hz Option 1DR Specifications Supplemental Information Spurious Responses Specifications Supplemental Information Terminated and 0 dB Attenuation 50 Ω KHz to 1.5 GHz − 90 dBm Option 1DQ Tracking Generator Option 1DN or 1DQOption 1DQa 50 Ω Option 1DN75 Ω Option 1DQ Option 1DNaReferenced to 50 MHz, 0 dB Attenuator Tracking Generator Output Accuracy 50 Ω Option 1DN Specifications Supplemental Information Output AttenuatorTracking Generator Output Accuracy 75 Ω Option 1DQ General Option A4H Option A4J 100 Specifications Supplemental Information Amptd Ref a Connector Type-N female Impedance 50 Ω NominalConnector BNC female Impedance 75 Ω Nominal 102 Chapter 103 104 Option 1AX Specifications Supplemental Information Gpib InterfaceSpecifications Supplemental Information Serial Interface Option A4H106 Chapter 107

E4403B, E4411B, E4408B specifications

Agilent Technologies, a leader in electronic measurement solutions, has developed a range of instruments that revolutionize the way engineers and scientists perform RF and microwave analysis. Among these, the E4408B, E4411B, and E4403B stand out as highly versatile and powerful tools suited for various applications ranging from telecommunications to aerospace.

The Agilent E4408B is a high-performance spectrum analyzer that boasts a frequency range from 3 Hz to 26.5 GHz, making it suitable for a wide array of RF measurements. Its key features include a high dynamic range and a low phase noise, which considerably enhance measurement accuracy. The E4408B incorporates advanced digital signal processing technology, enabling real-time analysis of signals with remarkable precision. With its large touchscreen interface, users can easily navigate complex measurements and visualize data in an intuitive manner.

Another significant instrument is the E4411B, a versatile power meter that excels in measuring various types of RF power. Capable of measuring both average and peak power, the E4411B offers a frequency range from 9 kHz to 6 GHz. This power meter is particularly valued for its high-speed measurement capabilities and high accuracy, supporting a wide range of application scenarios such as wireless communications and broadcasting. Its built-in memory and connectivity options allow users to log and analyze data efficiently, enhancing the overall workflow.

The Agilent E4403B is a signal analyzer that supports a frequency range from 9 kHz to 3 GHz. This instrument is primarily designed for the analysis of communication signals, and it features a frequency domain analysis capability that makes it indispensable for modern communication systems. With its intuitive user interface, the E4403B facilitates quick access to vital measurements, reducing measurement times significantly. The analyzer’s excellent IP3 (third-order intercept point) specifications ensure reliable signal integrity, essential for ensuring robust communications.

In summary, Agilent Technologies' E4408B, E4411B, and E4403B represent a strong suite of measurement tools equipped with advanced technologies and features. They provide engineers with the capabilities needed to perform precise RF and microwave measurements across various industries, making them invaluable assets in the development and testing of modern electronic systems. With their user-friendly interfaces and high-performance specifications, these analyzers contribute significantly to innovation in technology and communication.