Gentek 3980322, 3980423, 3980422, 3980200, 3980401, 3980403 High Performance Features and Safety

Page 34

Chapter 4: High Performance Features and Safety

19.The HEPA filter in the enclosure will gradually accumulate airborne particulate matter from the room and from work performed in the enclosure. The rate of accumulation will depend upon the cleanliness of the room air, the amount of time the enclosure is operating and the nature of work being done in the enclosure. With normal usage, the HEPA filters will last two to five years before requiring replacement.

20.Avoid direct exposure to ultraviolet (UV) radiation; NEVER work in the Purifier Class I Enclosure when the UV light is on.

21.Ensure that the filtered enclosure is connected to an electrical service in accordance with local and national electrical codes. Failure to do so may create a fire or electrical hazard. Do not remove or service any electrical components without first disconnecting the filtered enclosure from electrical service.

22.Use of an open flame must be avoided with the enclosure. Open flames may disrupt the airflow patterns in the enclosure and cause a fire hazard with volatile solvents.

23.Increase the face velocity by adjusting the speed control of the motorized impeller or change the HEPA filter when the face velocity falls below acceptable limits established by your Safety Officer.

24.Exhaust carbon filters and HEPA filters are disposed as hazardous waste. The user is responsible for recording the chemicals adsorbed or treated by the filters and disposing properly. HEPA filters should be decontaminated before disposal on Purifier enclosures.

25.Ensure only trained operators use the enclosure. New users should review the User’s Manual and become familiar with the operation of the enclosure.

26.If the filtered enclosure is to be used in a confined space, make sure the space is well ventilated and the concentration of toxic contaminants cannot accumulate greater than the TWA.

27.Proper operation of the enclosure depends largely upon the enclosure location and the operator’s work habits. The enclosure should be located away from traffic patterns, doors, fans, ventilation registers, fume hoods, and any other air-handling device that could disrupt its airflow patterns. Consult Chapter 2: Prerequisites and Chapter 3: Getting Started sections of this manual for further details.

29

Image 34
Contents User’s Manual USA Warranty Able Ontents PrerequisitesMaintaining Your Filtered Enclosure Chapter Introduction About This Manual IntroductionTypographical Conventions Getting StartedIntroduction Chapter Prerequisites Location and Air Current Requirements Support, Vibration and Movement RequirementsExhaust and Blower Requirements Electrical Requirements Space RequirementsPrerequisites Chapter Getting Started Lift by the front air foilUnpacking the Enclosure Do not move the enclosure by tilting it onto a hand truckWork Surface Specifications Work Surface and Hepa Filtered Enclosure InstallationFiltered Enclosure Installation Connecting to the Exhaust System Optional Getting Started Carbon Filters Accessory for Odor Control only Installation of Hepa Filters Accessory Odor Control CarbonHepa Filters Filter Type Appropriate Use 115V ModelsSet the Face Velocity with Speed Control Adjustment Validating the Vented EnclosureSealing the Filtered Enclosure to the Work Surface Chapter High Performance Features and Safety Precautions High Performance FeaturesHigh Performance Features and Safety 1510 Hepa Filtered Enclosure Airflow Diagram High Performance Features and Safety High Performance Features and Safety High Performance Features and Safety High Performance Features and Safety Safety Precautions High Performance Features and Safety High Performance Features and Safety High Performance Features and Safety Routine Daily Work Procedures PlanningWork Techniques Start-upLoading Materials and Equipment Final PurgingUnloading Materials and Equipment Suitable ApplicationsHepa Filter Applications Suitability and Guidelines ShutdownOdor Control Carbon Filter Applications sold as an accessory Definition of Terms Appropriate Chemicals for Odor Control Carbon Filters Chemical Carcinogen Use with Odor Control Carbon Filters Prohibited Acid Use Chapter Maintaining Your Filtered Enclosure Weekly Routine Maintenance ScheduleMonthly or more often as required Decontamination Determination of when to Replace Hepa FiltersAnnually How to Install a New Hepa Filter Hepa Filter Changing Diagram & Filter Leak Test Diagram Hepa Filter Leak Test PurposeAcceptance Calibrate and Operate the Airflow Monitor Labconco Airflow Monitor / Airflow Switch OperationGuardian Airflow Monitor LED Monitor Calibration Enclosure Operating In-Flow Alarm Condition Set Point Speed Guardian Airflow Monitor LED with Airflow Switch Maintaining Your Filtered Enclosure Odor Control Carbon Filter Replacement Procedure See Calculating Odor Control Carbon Filter Life Steps for Calculating PPM and Filter LifeFormaldehyde only Initial CertificationRe-Certification Ammonia onlyUV Light Replacement Fluorescent Light ReplacementMotorized Impeller Replacement Motorized Impeller Replacement Speed Control Replacement Chapter Accessorizing Modifying Your Filtered Enclosure Work SurfacesPart Description Guardian LED Airflow MonitorExhaust Transition Kits for Ducting to Outside Remote Blowers For Purifier Class I EnclosureFor Purifier Hepa Filtered Enclosure Exhaust Dampers Accessory Filters Hepa FilterOdor Control Carbon Filter Storage Cabinets Utility Shelf KitAccessorizing and Modifying Your Filtered Enclosure Chapter Troubleshooting Servicer Operating LOG Problem Cause Corrective ActionTroubleshooting Problem Cause Corrective Action Service Operating Record Log Date CommentsAppendix a Filtered Enclosure Components Replacement Parts Qty Part Number Description Qty Part Number Description 3788200 Snubber, Filter Pressure Gauge Hepa Appendix B Dimensions Exhaust Options Appendix B Dimensions and Exhaust Options Appendix B Dimensions and Exhaust Options Appendix C Filtered Enclosure Specifications Environmental ConditionsAppendix C Filtered Enclosure Specifications Appendix C Filtered Enclosure Specifications Appendix C Filtered Enclosure Specifications Appendix C Filtered Enclosure Specifications Appendix C Filtered Enclosure Specifications Ppendix Uick Hart Iltered Nclosures Model SizeNon-mandatory recommendations from Prudent Practices Appendix E References Nfpa 30 2000 Flammable and Combustible Liquids Code General References Laboratory Safety, Principles and Practices, American Page USA

3980203, 3980223, 3980402, 3980400, 3980422 specifications

Gentek has established itself as a leading name in the world of electrical and building materials, offering a wide range of products designed to meet the diverse construction and renovation needs. Among its impressive lineup, the model numbers 3980202, 3980323, 3980220, 3980221, and 3980201 have emerged as notable contenders, each boasting specific features that set them apart in the market.

The Gentek 3980202 is particularly acclaimed for its robust construction and exceptional durability. This product is designed with weather-resistant properties, making it suitable for various climates and ensuring that it can withstand harsh environmental conditions. Touted for its ease of installation, the 3980202 features a user-friendly design, allowing both professionals and DIY enthusiasts to utilize it without hassle.

Moving onto the Gentek 3980323, this model takes innovation to the next level with its advanced technological integrations. It incorporates energy-efficient solutions aimed at reducing overall electrical consumption. This model is also compatible with modern smart home systems, allowing users to enhance their homes with ease. The sleek design does not compromise on performance, ensuring that functionality and aesthetics work in harmony.

The Gentek 3980220 and 3980221 share several similarities, focusing on versatility and adaptability. These models are engineered to cater to a wide range of applications, making them ideal for both residential and commercial projects. Their modular designs allow for customization based on specific project requirements, significantly increasing their appeal to contractors and architects. Furthermore, they boast eco-friendly features, contributing to sustainable building practices.

Lastly, the Gentek 3980201 stands out for its affordability without compromising quality. This model offers essential features that meet the fundamental needs of any project, making it an excellent choice for budget-conscious buyers. Despite its economical price point, the 3980201 is crafted with high-grade materials ensuring reliability and longevity.

In summary, Gentek's models 3980202, 3980323, 3980220, 3980221, and 3980201 showcase the company's commitment to quality, innovation, and sustainability. Each model offers unique features tailored to specific needs, ultimately providing contractors, architects, and homeowners with dependable solutions that stand the test of time.