![](/images/new-backgrounds/1073703/737035x1.webp)
GEMINI 120A
UNPACKING
All products manufactured by the Wilbur Curtis Company are thoroughly inspected at the factory and are warranted to be free of all defects or faulty workmanship. The Gemini unit is packaged for
|
|
|
|
|
|
|
|
|
|
|
| maximum protection while being shipped. |
|
|
|
|
|
|
|
|
|
|
|
| Make sure the shipping carton is not damaged |
|
|
|
|
|
|
|
|
|
|
|
| |
|
| D | B |
| or punctured. Unpack the carton carefully, | |||||||
|
|
| inspecting the contents for any damage that | |||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
E |
|
|
|
|
|
|
|
|
|
| may have occurred in transit. Report any | |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| damage immediately to the freight company. |
|
|
|
|
|
|
|
|
|
|
|
|
G | FUNCTIONOFTHEGEMINI |
|
| A | The water in the heating tank A, is maintained |
F | at the same level at all times by a sensor | |
|
| called the water level probe B. This controls |
H | C | the water inlet valve C. |
| When the brew switch is pushed, a brew cycle | |
|
| |
|
| starts: The dump valve D, is opened by the |
|
| brew timer E, allowing hot water to be sprayed |
|
| over the ground coffee for a specific time |
|
| period . |
|
| Brewed coffee then pours from the brew cone |
|
| F, into the Satellite. |
|
| The hot water faucet G, dispenses hot water |
|
| for tea, instant beverages, or soups and can |
be used at any time without interrupting the brew cycle. A warmer element, H, keeps the coffee in the Satellite at the proper temperature.
NOTICE
This brewer must be installed by a professional licensed technician and must comply with all local electrical, mechanical and plumbing codes having jusrisdiction. Wilbur Curtis Company will not accept any responsibility if these conditions are not met. This machine must be used for it's in- tended purpose and the function for which it was designed.
SETUPINSTRUCTIONS
1.Locate a position for the Gemini 120A on a firm and level, counter top.
2.Remove the top cover of the brewer and lid from the heating tank. Hand fill the tank until the water level is approximately two (2) inches below the probe tip.
3.A 1/4" female flare fitting is required for water supply. Connect the water line to the inlet valve fitting and turn on the water.
4.With the top cover removed, turn thermostat stem clockwise until it stops.
5.Plug the unit into a power supply outlet and turn toggle switch on. Turn ON/OFF switch to ON position. Make sure water is flowing into the heating tank. Filling should stop when the water level reaches the probe tip. When this is verified, replace both tank lid and top cover to the machine.
6.Allow 15 to 20 minutes for the water in the tank to reach brewing temperature. The BREW READY light will come on when it reaches the correct temperature.
-1 -