Wibur Curtis Company CA 90640 warranty Problem Water not Flowing from Sprayhead

Page 6

GEMINI 120A

PROBLEM: WATER IN TANK DOES NOT GET HOT OR WATER TEMPERATURE TOO LOW

POSSIBLE CAUSE

SOLUTION

10. Defective thermostat

Thermostat may be cutting off before the water temperature reaches

 

operating temperature. Do not try to reset the thermostat. Replace it.

 

 

PROBLEM: WATER NOT FLOWING FROM SPRAYHEAD.

POSSIBLE CAUSE

SOLUTION

11. Water level is too low

Check water level in tank. If water is not flowing into the tank, review

in heating tank

steps 1 thru 4, previous page.

 

 

12. Defective brew switch

Check the continuity between terminals 5B and 4B when the BREW

(item #41)

switch is pressed. If there is no continuity, replace the switch.

 

 

13. Defective timer (item #2).

Make sure the timer is receiving 110 to 120 volts. You can verify this

 

by taking a reading with your meter at the end of the YELLOW wire

 

on terminal 5B of the ON/OFF switch and at terminal A of the timer.

 

When the timer is activated by the brew switch, you should read

 

110 to 120 volts across terminals 6 and A of the timer. The RED

 

wire on terminal 6 supplies power to open the dump valve. If no

 

voltage is present, replace the timer.

 

 

14. Burned out dump valve

If the timer works when the brew switch is pressed, then check the

coil (item #34)

dump valve using a voltmeter on the terminals. If it shows 110 to

 

120 volts but no water flows through the valve, clean out the valve or

 

replace the coil.

 

 

- 4 -

Image 6
Contents Gemini Commercial Coffee Brewing Systems Page Gemini 120A ADJUSTMENTINSTRUCTIONSFORTIMERWC-603RDS Trouble Shooting Problem Water not Flowing from Sprayhead Wiring Diagram Gem -5 & -8 120 Volts, 90 Watts Gemini 120A Gemini 120A Parts List Wiring Diagram GEM120A-10 Wiring Diagram GEM120A-63 Warranty