Hoshizaki MWH(-M), MWH KM-515MAH, MRH/3, MRH KM-901MAH, MRH KM-600MAH KM-650MAH, KM-320MAH

Page 4

5. Bin Control Selector or Harvest Pump Timer Operation (S4 dip switch 7)

48

6. Factory Use (S4 dip switch 8)

49

7. Freeze Timer (S4 dip switch 9 & 10)

49

8. Float Switch Selector (S5 dip switch 1): "G" Control Board

50

9. Refill Counter (S5 dip switch 2 through 5): "G" Control Board

50

D. Control Switch

50

IV. Refrigeration Circuit and Component Service Information

51

A. Refrigeration Circuit Service Information

51

B. Component Service Information

54

C. Water Regulating Valve Adjustment (water-cooled model)

54

V. Maintenance

55

VI. Preparing the Appliance for Periods of Non-Use

56

VII. Disposal

58

VIII. Technical Information

59

A. Specification Sheets

59

1. KM-320MAH

59

2. KM-320MWH

60

3. KM-515MAH

61

4. KM-515MWH

62

5. KM-515MRH

63

6. KM-600MAH

64

7. KM-650MAH

65

8. KM-650MWH

66

9. KM-650MWH-M

67

10. KM-650MRH

68

11. KM-901MAH

69

12. KM-901MWH

70

13. KM-901MRH

71

14. KM-901MRH3

72

B. Performance Data

73

1. KM-320MAH

73

2. KM-320MWH

74

3. KM-515MAH

75

4. KM-515MWH

76

5. KM-515MRH

77

6. KM-600MAH

78

7. KM-650MAH

79

8. KM-650MWH

80

9. KM-650MWH-M

81

10. KM-650MRH

82

11. KM-901MAH

83

12. KM-901MWH

84

13. KM-901MRH

85

14. KM-901MRH3

86

4

Image 4
Contents Modular Crescent Cuber Models KM-320MAH, MWH Hoshizaki AMERICA, INC Contents Page Page Important Safety Information Additional Warning for Remote Models Air-Cooled Models MAH Construction and Water/Refrigeration Circuit DiagramModel Shown KM-515MAH Water-Cooled Models MWH-M Model Shown KM-515MWHRemote Models MRH/3 Model Shown KM-901MRHWater/Refrigeration Circuit Diagram Discharge Line Freeze Pump- Out Sequence of Operation Flow Chart Timer OperationG Control Board without Harvest Pump Minute Harvest Cycle Freeze Cycle Pump-Out CycleIcemaker Off Ice Level Lowered Bin FullIcemaker Off Timer Control Board with Harvest PumpService Diagnosis G Control Board without Harvest Pump Timer Diagnosis Page Page Page OFF Shutdown Control Board Thermostatic Bin Control TBC Mechanical Bin ControlControl Board with Harvest Pump Timer Diagnosis Page Page Page Every cycle After 2nd freeze cycle Shutdown Mechanical Bin Control Control Board Check Control Correct LED BoardBin Control Check Thermostatic Bin Control CheckCycle at Shutdown Mechanical Bin Control Activation Mechanical Bin Control CheckMechanical Bin Control Cleaning Model Shown KM-901MH/3Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Thermistor Check No Ice Production Diagnostic TablesNo Ice Production Possible Cause Freeze-Up Freeze-Up Possible Cause Harvest CycleFreeze-Up Possible Cause Low Ice ProductionLow Ice Production Possible Cause Long Harvest Cycle Low Ice Production Possible Cause Long Freeze Cycle III. Controls and Adjustments Control Board Control Board LayoutControl Board Part Number 2A3792-01 LED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Every 3 secSequence Step Energized Time LEDs are On Components Min Max AvgControl Board Settings and Adjustments Default Dip Switch SettingsS4 Dip Switch G Control Boards S5 Dip Switch Control Board OnlyPump-Out Timer S4 dip switch 3 Harvest Timer S4 dip switch 1S4 Dip Switch Setting Time Sec Control Board 1st Pump-Out S4 Dip Switch Setting Frequency Pump-Out Frequency Control S4 dip switch 5Bin Control Factory Use S4 dip switch Freeze Timer S4 dip switch 9Control Board S4 Dip Switch Setting Pump Motor Time sec S4 Dip Switch Setting Time MinFloat Switch Selector S5 dip switch 1 G Control Board Control SwitchRefill Counter S5 dip switch 2 through 5 G Control Board Refrigeration Circuit Service Information IV. Refrigeration Circuit and Component Service InformationRefrigerant Recovery Brazing Evacuation and Recharge R-404APage Water Regulating Valve Adjustment water-cooled model Component Service InformationComponent Maintenance Schedule MaintenanceFrequency Area Task Remove the water from the icemaker water line VI. Preparing the Appliance for Periods of Non-UseRemove the water from the water tank Page VII. Disposal VIII. Technical Information Specification Sheets KM-320MAHKM-320MWH Water Cooled CondenserKM-515MAH KM-515MWH KM-515MRH KM-600MAH KM-650MAH KM-650MWH Awaiting Data KM-650MWH-MKM-650MRH KM-901MAH KM-901MWH KM-901MRH KM-901MRH3 Performance Data 352 337730 430501 435980 1090500 436940 960491 4521000 198592 5031040 1190661 5621180 1290620 10801060 744Awaiting Data 632 5641220 1320874 7321600 1710912 8271480 1550889 7851590 1770899 8151670 1830Wiring Diagrams Diagrams Without Harvest Pump Timer RelaysKM-650MAH, KM-650MWH, KM-901MAH, KM-901MWH KM-650MRH, KM-901MRH KM-901MRH3 Diagrams With Harvest Pump Timer Relays KM-515MAHKM-650MAH, KM-650MWH, KM KM-650MWH-M KM-650MRH
Related manuals
Manual 50 pages 28.96 Kb Manual 40 pages 33.48 Kb

KM-320MAH, MRH KM-600MAH KM-650MAH, MWH(-M), MRH KM-901MAH, MRH/3 specifications

Hoshizaki, a leading manufacturer in the food service equipment sector, offers a diverse range of ice-making machines that excel in efficiency, durability, and innovative technology. Among the notable models are the Hoshizaki MWH KM-515MAH, MWH(-M), MRH KM-901MAH, MRH KM-600MAH, KM-650MAH, and KM-320MAH. Each model brings unique features designed to meet varying commercial ice production needs.

The Hoshizaki MWH KM-515MAH is particularly recognized for its high ice production capacity, generating up to 515 pounds of ice per day. This model incorporates advanced technology that ensures consistent ice quality and purity. The MWH(-M) variant often includes modifications to suit specific operational environments, ensuring reliability in diverse settings.

Similarly, the MRH KM-901MAH stands out with its ability to produce a staggering 901 pounds of ice per day, making it ideal for high-volume establishments. This model is equipped with Hoshizaki's unique "cubelet" technology, producing a soft, chewable ice perfect for beverages. It also features a robust stainless steel construction, enhancing its durability and resistance to corrosion.

The MRH KM-600MAH offers 600 pounds of daily ice output, while the KM-650MAH enhances that capacity to 650 pounds. Both machines prioritize energy efficiency and come with built-in energy-saving modes. These models feature advanced ice sensing technology that monitors production levels to optimize energy consumption and reduce waste.

On the other hand, the KM-320MAH is designed for smaller establishments, with a daily ice production rate of 320 pounds. Despite its smaller footprint, it maintains high production efficiency and is equipped with features like a built-in storage bin, saving space while ensuring a reliable ice supply.

Across these models, Hoshizaki employs various technologies, including air-cooled and water-cooled systems, offering flexibility depending on installation requirements. The ice machines are designed with user-friendly controls and features like self-cleaning capabilities, making maintenance straightforward and less time-consuming.

In summary, Hoshizaki's ice machines, including the MWH KM-515MAH, MRH KM-901MAH, and others, deliver exceptional ice production, durability, and efficiency tailored to meet the demands of any commercial kitchen or service establishment. With a commitment to quality, Hoshizaki continues to be a trusted choice for businesses needing reliable ice-making solutions.