Hoshizaki KM-250BAF, KM-250BWF instruction manual Location, Electrical Connection

Page 9

2. Location

IMPORTANT

This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within +45°F (7°C) to +100°F (38°C); Normal operating water temperature should be within +45°F (7°C) to +90°F (32°C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect production capacity.

For best operating results:

Icemaker should not be located next to ovens, grills or other high heat producing equipment.

Level the icemaker from side-to-side and front-to-rear by adjusting the legs. Location should provide a firm and level foundation for the equipment.

Allow 6" (15 cm.) clearance at rear and top for ease of maintenance and/or service should they be required.

3. Electrical Connection

This icemaker must have a separate power supply or receptacle of proper capacity. See the nameplate.

Usually an electrical permit and services of a licensed electrician are required.

9

Image 9
Contents SELF-CONTAINED Crescent Cuber KM-250BAF KM-250BWF Hoshizaki AMERICA, INC Contents KM-250BAF air-cooled Specifications Nameplate RatingKM-250BWF water-cooled KM-250BAF Dimensions/ConnectionsKM-250BWF Page Electrical Connection LocationWater Supply and Drain Connections See Fig KM-250BAF KM-250BWF Final Check List Startup Preparing the Icemaker for Long Storage Page Cleaning and Sanitizing Instructions III. Cleaning and MaintenanceCleaning Solution Cleaning ProcedurePage Sanitizing Procedure Sanitizing SolutionPage Maintenance Hoshizaki