19INSTALL LIGHT BULB

NOTE: A light bulb is not shipped with the hood. Obtain one locally. Purchase and install an ordinary screw-base light bulb, not more than 60 watts.

20FOLLOW ELECTRICAL CODE

Complete the electrical wiring according to National Electrical Code and local codes.

NOTE: This hood must be permanently grounded.

Connect house wiring (120 VAC) to hood wiring.

23REPLACE FILTER

Make sure fan blade turns freely and replace the filter. NOTE: On model JV347, install the metal grease filter if ducted or the charcoal filter if recirculated.

Metal grease filter or charcoal filter

The installation is complete. Turn on power at service panel, and test for proper operation.

21CONNECT WIRING

Connect house black to hood black wire, house white to hood white wire and house ground under green ground screw. Securely tighten the strain relief clamp onto the house wiring.

Green ground screw

WARNING: IMPROPER CONNECTION OF ALUMINUM HOUSE WIRING TO THESE COPPER LEADS CAN RESULT IN A SERIOUS PROBLEM. USE ONLY CONNECTORS DESIGNED FOR JOINING COPPER TO ALUMINUM AND FOLLOW THE MANUFACTURER’S RECOMMENDED PROCEDURE CLOSELY.

22 REPLACE WIRING COVER

Wiring cover

TROUBLESHOOTING CHECKLIST

If the hood seems to be operating at high speed when the control is not set on high, or if ventilation seems inadequate, check the following:

Knockouts not removed from hood.

Damper blade not opening.

Reduced airflow because the duct is too small or the duct length is too long.

The duct is blocked.

Undersized or restrictive wall or roof cap.

If the hood seems to make excessive noise:

Fan may be hitting the filter. Turn off the fan and remove the filter. Bend the filter down slightly in the center (into a dome shape) to allow fan clearance. Reinstall and adjust as needed.

The fan does not work but the lights do:

Switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Check the wiring connections. See the CONNECT WIRING section in these Installation Instructions.

14

Image 14
Contents Range Hoods Safety Precautions Avertissement Réduisez LE Using the hood controls Instructions Installation Instructions Range Hood Ductwork RequirementsInstallation Instructions WORKSHEET-CALCULATE Total Equivalent Ductwork LengthTools YOU will Need Damage SHIPMENT/INSTALLATIONMounting Space Parts IncludedChoose Vent Option Remove Wiring Knockout Remove Wiring CoverReverse the Baffle for Ducted Installations only Remove Exhaust AdaptorFor 7″ Round Vertical Ducted Discharge Installations only For RECESSED-BOTTOM Cabinets onlyCUT Holes RUN WiresMark Holes Screw in Partway Optional Power Cord KIT JXHC1Feed in Wires Secure HoodReplace Wiring Cover Install Light Bulb Follow Electrical CodeConnect Wiring Troubleshooting ChecklistGE Range Hood Warranty Consumer Support GE Appliances Website