Aquachlor C Standard | Aquachlor SC Self Clean | ||||
C | Standard | C Replacement Cell |
| SC Self Clean | SC Replacement |
Systems Model | Model to order |
| Systems Model | Cell Model to order | |
260 |
| 260 |
| 250 | 250 |
390 |
| 390 |
| 330 | 330 |
520 |
| 520 |
|
|
|
SC SYSTEMS Please Note that unless you have extreme water conditions the Cell should not become scaled and you should not have to clean the Cell. In areas of extremely hard water it may be necessary to clean your cell periodically. Refer below.
To clean the cell, remove all leads connected to the Head Assembly. Unscrew the Cell by turning the Head Assembly clockwise – as per instructions, and withdraw from the Cell Housing.
METHOD 1
Add 1 part HYDROCHLORIC ACID to 5 parts WATER in a suitable container and immerse the Cell in this solution. It should not take longer than a few minutes to clean, if it does the Cell should be cleaned more frequently. If the build – up is not excessive it may be possible to clean the plate with a jet of running water. Return the Cell to its Housing and connect leads to the Head Assembly.
METHOD 2
As an alternative, an approved commercial Cell cleaning solution can be used a number of times effectively.
SAFETY DEVICE:
Hydrogen Gas is a by – product of the chlorine producing process. A Gas Sensor has been incorporated into the Unit and Cell, which will switch off chlorination if gas is detected in the Cell Housing or there is no water flow.
Aquachlor Units are also fitted with a Thermal Cut – Out to prevent overheating. If the temperature rises too high, power is automatically disconnected. The Unit will resume operation when it cools down.
DAY TO DAY OPERATION:
Four Prime rules must be observed if your unit is to give the best possible service:
1. STABILISER
The importance of pool stabiliser cannot be over – emphasised. It is essential in helping retain chlorine in your pool. Chlorine is rapidly dissipated by sunlight and the use of stabiliser will reduce this dissipation substantially. Without stabiliser, it may be necessary to run the Unit for up to three times as long!
8