WARNING

HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY. FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS.

Read and understand all instruction manuals before operating equipment.

FLUID INJECTION HAZARD

General Safety

This pressure washer generates very high fluid pressure. Spray from the gun, leaks or ruptured components can inject fluid through your skin and into your body and cause extremely serious bodily injury including the need for amputation. Also, fluid injected or splashed into the eyes or on the skin can cause serious damage.

NEVER point the spray gun or wand at anyone or at any part of the body . NEVER put hand or fingers over the spray tip.

ALWAYS follow the Pressure Relief Procedure, before cleaning or servicing any part of the sprayer.

NEVER try to stop or deflect leaks with your hand or body.

Be sure equipment safety devices are operating properly before each use.

Medical Treatment

If any fluid appears to penetrate your skin, get

EMERGENCY MEDICAL TREATMENT AT ONCE. DO NOT TREAT AS A SIMPLE CUT. Tell the doctor exactly what fluid was injected.

NOTE TO PHYSICIAN: Injection in the skin is a traumatic injury. It is important to treat the injury surgically as soon as possible. Do not delay treatment to research toxicity. Toxicity is a concern with some exotic coatings injected directly into the bloodstream. Consultation with a plastic surgeon or reconstructive hand surgeon may be advisable.

Pressure Relief Procedure

To reduce the risk of serious bodily injury, including fluid injection and splashing in the eyes or on the skin, always follow this procedure whenever you stop spraying for more than 10 minutes, when shutting down, and before checking or repairing any part of the system.

1.Engage the trigger safety latch.

2.Turn the sprayer off.

3.Remove the ignition cable from the spark plug.

4.Shut off the water supply.

5.Disengage the trigger safety latch and trigger the gun to relieve pressure, and then engage the trigger safety latch again.

6.Before long–term (overnight) storage or transporting of the unit, disconnect the water supply and turn off the fuel supply valve.

Spray Gun Safety Devices

Be sure all gun safety devices are operating properly before each use. Do not remove or modify any part of the gun; this can cause a malfunction and result in serious bodily injury.

SAFETY LATCH: Whenever you stop spraying for a moment, always set the gun safety latch in the engaged or “safe” position, making the gun inoperative. Failure to properly set the safety latch can result in accidental triggering of the gun.

SPRAY TIP SAFETY : Use extreme caution when cleaning or changing spray tips. If a spray tip clogs while

spraying, engage the gun safety latch immediately

.

ALWAYS follow the Pressure Relief Procedure

and

then remove the spray tip to clean it.

 

MOVING PARTS HAZARD

Moving parts can pinch or amputate fingers or other body parts. KEEP CLEAR of moving parts when starting or operating the pressure washer.

NEVER operate the pressure washer without all guards and interlocks installed and functioning. Follow the

Pressure Relief Procedure

before checking or

servicing the pressure washer to prevent discharging high pressure fluid from the gun.

Warnings continued on page 4.

308–530 3

Page 3
Image 3
Graco Inc 308-530, 800-700, 800-699 manual Moving Parts Hazard, General Safety, Medical Treatment, Pressure Relief Procedure

800-700, 308-530, 800-698, 800-699 specifications

Graco Inc is a renowned manufacturer specializing in fluid handling systems used in a variety of applications, particularly in industries such as construction, automotive, and manufacturing. Among their extensive product lineup, models 800-699, 800-698, 308-530, and 800-700 stand out for their innovative features and advanced technologies.

The Graco 800-699 is a versatile air-operated double diaphragm pump designed for high efficiency and reliable performance. Its robust construction includes a corrosion-resistant housing ideal for handling tough fluids. The pump can effectively operate at various pressures, making it suitable for tasks ranging from transferring chemicals to applying coatings. With its easy maintenance design, operators can quickly access key components, minimizing downtime.

Model 800-698 shares similar attributes but is distinguished by its emphasis on portability and ergonomic design. This pump model is lightweight and features a compact form factor, allowing easier transport and setup for mobile applications. Its intuitive controls enable precise flow rate adjustments, giving operators enhanced control over their fluid-handling tasks. Additionally, it is designed for compatibility with a wide range of fluids, enhancing its versatility across different applications.

The 308-530 model is notable for its electric-driven technology. This feature makes it ideal for environments where compressed air is not available or where a quieter operation is required. The 308-530 is equipped with advanced control systems that optimize energy consumption without compromising performance. Moreover, its integrated safety features ensure reliable operation while protecting both the equipment and the operator.

Finally, the Graco 800-700 represents the pinnacle of efficiency in fluid transfer systems. This model utilizes state-of-the-art technology to provide faster flow rates and improved material compatibility. The 800-700 is engineered to handle a wide range of viscous materials, making it perfect for heavy-duty applications. The modular design allows for easy upgrades, ensuring users can keep pace with emerging technologies without extensive disruptions to their operations.

Collectively, these Graco models embody a commitment to quality, durability, and user-friendly design, allowing companies to streamline their processes and enhance productivity in fluid handling tasks. With ongoing advancements and a focus on customer satisfaction, Graco Inc continues to be a leader in this industry.