Installation
Installation
15V821 Dump Valve Kit for Wall Panel
NOTE: These instructions show this kit being installed on the A side. It may also be installed on the B side.
1.Shut off the fluid supply to the dose valve (V) at the front of the wall panel.
2.Actuate the dose valve to relieve fluid pressure in the valve.
3.Relieve fluid pressure upstream and downstream of the dose valve. See your ProMix 2KS Operation Manual.
4.See FIG. 1. Remove the plug from the dose valve adapter. Install the street elbow (18) in this port. Install the nipple (19) in the elbow.
5.Install the dump valve assembly (includes 1, 2, 4, and 11) in a slot of the flange (F) at the back of the wall panel. Secure with the nut (8).
6.Install the elbow (6) in the open port of the dump valve adapter (2). Connect a 1/4 npsm(f) hose (12) between the elbow (6) and nipple (19).
7.Shut off all power to the fluid panel. Open the fluid panel. See the Wall Panel detail in FIG. 2. Install the solenoid (9) at the correct position (Dump Valve A or Dump Valve B) on the solenoid manifold. Con- nect the solenoid wires to the fluid panel control board as shown in FIG. 3. Also see the System Electrical Schematic on page 13.
8.Connect the tubing (7) between the solenoid mani- fold and the tube fitting (T) on the dump valve (1). See System Pneumatic Schematic, page 10.
At Front of Wall Panel | At Back of Wall Panel |
A SIDE | B SIDE |
1
12 |
|
|
|
|
|
V |
|
|
|
| 12 |
|
|
|
|
| |
|
|
| T |
|
|
|
| 18 | F |
| 6 |
|
|
|
| ||
|
|
|
|
| |
19 | TI12744a |
| 8 | 2 | TI12743a |
FIG. 1: 15V821 Kit Installation
312786G | 3 |