Installation
15V822 Dump Valve Kit for RoboMix
NOTE: These instructions show this kit being installed on the B side. It may also be installed on the A side.
1.See FIG. 7. Shut off the fluid supply to the dose valve (V) in the RoboMix.
2.Actuate the dose valve to relieve fluid pressure in the valve.
3.Relieve fluid pressure upstream and downstream of the dose valve. See your ProMix 2KS Operation Manual.
4.Remove the plug from the dose valve adapter. Apply thread sealant and install the elbow (8) in this port.
5.Install the valve adapter (3) in the RoboMix. Secure with four screws (11). Apply thread sealant and install the nipple (9) through the back of the Robo- Mix and into the adapter. Install the swivel (6) in the opposite side of the adapter.
6.Install the seat (2),
7.Connect the hose (5) between the swivel (6) and elbow (8).
8.Shut off all power to the fluid panel. Open the fluid panel. See the RoboMix Panel detail in FIG. 2. Install the solenoid (4) at the correct position (Dump Valve A or Dump Valve B) on the solenoid manifold. Connect the solenoid wires to the fluid panel control board as shown in FIG. 3. Also see the System Electrical Schematic on page 13.
9.Connect the tubing (13) between the solenoid mani- fold and the tube fitting (T) on the dump valve (1). See System Pneumatic Schematic, page 10.