A-1

INSTALLATION

A-1

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS – COOL ARC® 40

 

 

 

Product No. / Model

K2187-2 (COOL ARC® 40 230V International)

 

 

 

 

 

 

Via Continental European (SCHUKO)- PRONG PLUG

 

 

 

 

 

 

 

 

 

 

 

 

Input

220-240VAC

50/60 Hz 1 Phase

 

 

 

 

 

 

 

 

 

 

 

Current Draw @ 60Hz Input

1.3-1.7 Amps

 

 

 

 

 

 

 

 

 

 

 

Current Draw @ 50Hz Input

2.0-2.4 Amps

 

 

 

 

 

 

 

 

 

 

 

Maximum Operating Pressure and Flow Rate

60 psi (414 kPa) (4.14 bar)Max.

 

 

 

(Open Flow, Without Welding Torch Restriction)

1.66 gal/min. (6.28 liter/min) Max.

 

 

 

 

 

 

 

 

 

 

 

Typical Operating Pressure and Flow Rate

53-57 psi (365-393 kPa)

 

 

 

(With Welding Torch Restriction)

.45-.60 gal/min. (1.7-2.3 liter/min)

 

 

 

 

 

 

 

 

 

 

 

Reservoir Size

2.0 ga. (7.6 liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Use Above Freezing: Use Clean tap, distilled or de-ionized water.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Use Below Freezing: Use 50% water and 50% pure ethylene glycol

 

 

 

 

 

 

(reagent

or industrial grade) mixture.

 

 

 

 

 

 

DO NOT USE: Automotive anti-freeze that contains rust inhibitors or leak stoppers.

 

 

 

Recommended Coolant

These coolants will damage the pump and block the small internal passageways of the

 

 

 

 

 

 

heat exchanger, affecting cooling performance. To acquire the proper coolant contact

 

 

 

 

 

 

a local welding distributor.

 

 

 

 

 

 

 

 

DO NOT USE: Pre-packaged welding industry coolants. These coolants may contain

 

 

 

 

 

 

oil-based substances, which attack the plastic components of the cooler. Once added

 

 

 

 

 

 

to the cooler, these substances are impossible to purge from the water lines and heat

 

 

 

 

 

 

exchanger.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shipping

46.5 lbs. (21.1 kg)

 

 

 

Weight

 

 

 

 

 

 

 

 

 

 

 

Reservoir

61.2 lbs. (27.8 kg)

 

 

 

 

 

 

 

 

 

 

Full (Water)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

9.03 in. (229.4mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

W

9.10 in. (231.1mm)

 

 

 

Dimensions

 

 

 

 

 

 

 

 

31.99 in. (812.6mm)

 

 

 

 

 

H (Top Face)

 

H Top Handle)

34.26 in. (870.2mm)

EXPLANATION OF SYMBOLS THAT APPEAR ON THIS EQUIPMENT

ON

OOFF

COOL ARC® 40

Image 8
Contents Cool ARC 40 Stand Alone Safety California Proposition 65 WarningsElectric Shock can kill IiiSAFETY IiiPrécautions DE Sûreté Please Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Installation OFFInstallation Electric Shock can killUnpacking the COOL-ARC40 Filling the Coolant ReservoirWater or Coolant Line Connections to the Cool ARC See Parts Lists for Itemʼs belowCoolant in and OUT Connections Input Power Connection Installation on Undercarriage or Power SourceHorizontal Installation on the TOP of a Power Source K559-3 K559-2Installation of Water Cooled Accessories Connection to Wire FeedersOperation Product DescriptionCooling Efficiency For exampleAccessories Optional Equipment Field InstalledMaintenance Inspect Condition of Coolant Coolant Treatment RecommendationPump Inlet Strainer Service the Pumps Inlet Strainer Additional Service NotesRemoving Coolant Add coolantTroubleshooting HOW to USE Troubleshooting GuideProblems SymptomsRecommended Course of ActionDiagrams M20078Dimension Print Cool ARC Aviso DE Keep your head out of fumes Turn power off before servicing