Lincoln Electric IM911 Input Power Connection, Installation on Undercarriage or Power Source

Page 11

A-4

INSTALLATION

A-4

Remove the connector nut from the INLET hose by making a straight cut 6-12 mm (1/4"-1/2") away from the end of the nipple located inside of the hose. Take the nipple and the connector nut ordered above and insert the nipple into the connector nut so that the threaded end of the connector nut points away from the barbed end of the nipple. Twist the barbed end of the nipple into the hose until the shoulder of the nip- ple is flush with the end of the hose. Secure the hose onto the nipple with the hose clamp to insure that the connection is watertight. No water can leak from the connection if it is properly attached. Repeat the proce- dure for the OUTLET hose. When complete, follow the connection procedure detailed above for connecting the hoses to the COOL ARC® 40 fittings.

The connector and nipple listed fit tightly onto 4.0 mm

(5/32") to 4.8 mm (3/16") inner diameter hose, but if clamped tightly to the hose, can fit up to a 6.4 mm (.25”) inner diameter hose.

INPUT POWER CONNECTION

Plug the input power cord on the COOL ARC® 40 into a standard 230V circuit breaker protected receptacle.

INSTALLATION ON UNDERCARRIAGE OR POWER SOURCE

The COOL ARC® 40 can be mounted either horizon- tally or vertically on a power source. To mount the cooler horizontally, order the K559-2 Cooler Horizontal Mounting Bracket. To mount the cooler ver- tically on a power source with a dual cylinder under- carriage, order K559-3 Cooler Vertical Mounting Bracket.

HORIZONTAL INSTALLATION ON THE TOP OF A POWER SOURCE

For proper installation, follow the instructions provided with the K559-2 Cooler Horizontal Mounting Bracket Kit. The cooler is secured to the power source lift bale. Reference the table below for a list of power sources that allows the COOL ARC® 40 to be mounted hori- zontally on top.

VERTICAL INSTALLATION ON POWER SOURCE WITH A DUAL CYLINDER UNDERCARRIAGE.

For proper installation, follow the instructions provided with the K559-3 Cooler Vertical Mounting Bracket Kit. The cooler is securely mounted to the dual cylinder support bracket. Reference the table below for a list of power sources and dual cylinder undercarriages that allows the COOL ARC® 40 to be mounted vertically at the rear of the machine on the gas bottle rack.

WARNING

If the COOL ARC® 40 is not securely mounted horizontally on top of a power source or vertically on a dual cylinder undercarriage, THE COOL ARC® 40 MUST BE OPERATED IN THE HORIZON- TAL POSITION. This will prevent the cooler from being accidentally tipped over.

------------------------------------------------------------------------

 

K559-3

K559-2

 

Cooler Vertical Mounting

Cooler Horizontal

Power Source

Bracket on a Dual

Mounting Bracket

 

Cylinder Undercarriage

Can be used On Top

 

 

of a Power Source

CV-300

K874 Undercarriage

Yes

CV-400

Not Available

Yes

CV-655

Not Available

Yes

DC-250

Not Available

Yes

DC-400

Not Available

Yes

DC-600, DC-655

Not Available

Yes

Square Wave TIG 275

K932-1 Undercarriage

No

Square Wave TIG 355

Not Available

Yes

Power Wave 455

K1570-1 Undercarriage

No

Power MIG 255

Not Available

No

 

 

 

COOL ARC® 40

Image 11
Contents Cool ARC 40 Stand Alone California Proposition 65 Warnings SafetyElectric Shock can kill Iii IiiSAFETYPrécautions DE Sûreté On-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents OFF InstallationFilling the Coolant Reservoir InstallationElectric Shock can kill Unpacking the COOL-ARC40Water or Coolant Line Connections to the Cool ARC See Parts Lists for Itemʼs belowCoolant in and OUT Connections K559-3 K559-2 Input Power ConnectionInstallation on Undercarriage or Power Source Horizontal Installation on the TOP of a Power SourceConnection to Wire Feeders Installation of Water Cooled AccessoriesProduct Description OperationFor example Cooling EfficiencyOptional Equipment Field Installed AccessoriesMaintenance Inspect Condition of Coolant Coolant Treatment RecommendationPump Inlet Strainer Add coolant Service the Pumps Inlet StrainerAdditional Service Notes Removing CoolantHOW to USE Troubleshooting Guide TroubleshootingCourse of Action ProblemsSymptoms RecommendedM20078 DiagramsDimension Print Cool ARC Aviso DE Keep your head out of fumes Turn power off before servicing