Jackson 24LTP, 24 LT technical manual Troubleshooting Section, When Testing the Machine

Page 15

TROUBLESHOOTING SECTION

WARNING: Inspection, testing and repair of electrical equipment should only be performed by a qualified service technician. Many of the tests require that the unit have power to it and live electrical components be exposed. USE EXTREME CAUTION

WHEN TESTING THE MACHINE.

Problem: Nothing on the machine operates; power switch is on and the power light is off.

1.The circuit breaker may be tripped. Reset the circuit breaker. If the breaker trips again, contact an electrician immediately to verify the machine’s amp draw and breaker size.

2.The machine may not be plugged into the wall. Plug the machine in.

3.The power cord many not be connected correctly at the terminal block. Verify and correct as required.

Problem: The machine does not fill. The power switch is on, the power light is on and the rinse/fill light is off.

1.The door is not completely closed. Close the door.

2.Faulty cam timer/cam timer microswitch. Ensure that the timer is wired correctly and that it is receiving power. If the timer is moving, replace the fill microswitch.

3.Faulty door switch. Ensure that the striker plate is activating the door switch. Check the switch wiring. If everything appears to be correct, then replace the switch.

Problem: The machine will not fill. The power switch is on, the power light is on and the rinse/fill light is on.

1.No incoming water. Ensure that water is hooked to the machine and that all service valves are open. Ensure that the water is at

20A5 PSI flow pressure.

2.Faulty rinse solenoid valve. Check the wiring of the solenoid valve. If it is correct replace the coil or valve as required.

3.Obstruction in the water line. Remove the obstruction.

Problem: Wash temperature is lower than expected.

1.Low incoming water temperature. Verify that the incoming water temperature is as indicated on the machine data plate.

2.Defective temperature gauge. Replace the gauge.

3.Faulty rinse solenoid valve. Verify that the rinse solenoid valve is working. If not, repair or replace as required.

Problem: The machine fills slowly (rinse is weak).

1.Low incoming water pressure. Verify that the incoming water is at 20A5 PSI flow pressure. If not, adjust as required.

2.Clogged or obstructed rinse tube plate. Verify that the component os free from debris and soil.

3.Clogged or obstructed incoming water line. Remove the obstruction.

Problem: The machine fills excessively.

1.Faulty rinse solenoid valve. Check the wiring of the solenoid valve. If it is correct replace the coil or valve as required.

2.Fill cam is out of adjustment. Adjust the fill cam to ensure a proper water level.

3.Incoming water pressure is too high. Verify that the incoming water is at 20A5 PSI flow pressure. If not, adjust as required.

Problem: Wash tank water level is too low.

1.Low incoming water pressure. Verify that the incoming water is at 20A5 PSI flow pressure. If not, adjust as required.

2.Fill cam is out of adjustment. Adjust the fill cam to ensure a proper water level.

3.Drain valve is leaking. Remove the drain hose to verify that the valve is not obstructed. If the valve is clear, but does not seal prop- erly, it should be replaced.

Problem: Dishes are not coming clean.

1.Low incoming water pressure. Verify that the incoming water is at 20A5 PSI flow pressure. If not, adjust as required.

2.Clogged or obstructed rinse tube plate. Verify that the component os free from debris and soil.

3.Chemicals are not being provided in the correct concentrations. Contact your chemical representative to verify chemical concentra- tions and dispenser operation.

12

Image 15
Contents Technical Manual Page Table of Contents Specifications Installation Instructions Installation Instructions Chemical Dispensing Equipment To Prepare Pumps for OperationPriming Chemical Feeder Pumps Detergent Control Operation Instructions Conserver 24LT CAM Timer Operation Instructions Conserver 24LT CAM Timer Operation Instructions Conserver 24LTP CAM Timer Operation Instructions Conserver 24LTP CAM Timer Operation Instructions Preventative Maintenance When Testing the Machine Troubleshooting SectionProblem Door drops hard and will not stay closed Problem Water flooding from the machineProblem Water leaks from the vacuum breaker Dimensions DimensionsQTY Description Control Panel AssemblyElectrical Panel Assembly Ordering Replacement Wire Tubing Ordering Replacement Conduit & FITTINGS/HOSE & TubingConduit Hose Conduit FittingsKick Plate Assembly Chemical Feeder Pump Mounting Assembly Chemical Feeder Pump Assembly Chemical Feeder Pump Wiring Assembly Incoming Plumbing Assembly Vacuum Breaker Assembly Wash Arm AssemblyVacuum Breaker & Wash ARM Assemblies Complete Vacuum Breaker Assembly Solenoid Valve & 1/2 NPT Vacuum Breaker Repair Parts KitsComplete 110 Volt Solenoid Valve Assembly Coil & Housing onlyWash Manifold Assembly Drain Plumbing Assembly Drain Valve Assembly Wash Motor to Wash TUB Assembly Wash Motor Assembly Door Assembly Miscellaneous Door SUB-ASSEMBLIES Door Latch AssemblyMiscellaneous Parts 5700-011-73-86 FRAME, SHROUD, & Panel ComponentsConserver 24LT Electrical Diagram Volt 60 Hertz Single Phase Page Model Serial No Installation Date Service Rep. Name Phone No Important Information Data Sheet

24LTP, 24 LT specifications

The Jackson 24 LT and 24LTP are cutting-edge portable lighting solutions designed for professional use in various environments. These models are part of Jackson's commitment to providing top-quality lighting with innovative technology and versatility, making them ideal for both indoor and outdoor applications.

One of the standout features of the Jackson 24 LT and 24LTP is their impressive lumen output, which ensures high visibility and bright illumination even in large spaces. The lights are equipped with advanced LED technology that maximizes brightness while minimizing energy consumption. This is particularly beneficial for users looking to reduce their carbon footprint and operating costs.

Both models boast a rugged construction that withstands the rigors of professional use. The durable housing protects the internal components from damage due to impact, moisture, and dust, making them suitable for a wide range of demanding environments, including construction sites, event venues, and outdoor festivals. Additionally, the lightweight design allows for easy transport and setup.

The Jackson 24 LT features adjustable brightness settings, allowing users to customize the light output according to their specific needs. This versatility is complemented by a range of color temperature options, ensuring that the lighting can be tailored for different applications, such as warm lighting for relaxed events or cooler temperatures for more intense work settings.

The 24LTP model takes this customization even further with integrated smart technology. Users can control the lighting remotely via a dedicated mobile app, providing functionality such as scheduling, dimming, and color selection from a distance. This smart feature is not only convenient but also enhances the overall user experience by making it easier to adapt the lighting to changing conditions or requirements.

Another key characteristic of the Jackson 24 LT and 24LTP is their low maintenance needs. With a long operational lifespan and no requirement for frequent bulb replacements, users can focus on their tasks without worrying about regular upkeep.

In conclusion, the Jackson 24 LT and 24LTP stand out as versatile, durable, and technologically advanced lighting solutions. Whether for professional events, construction projects, or outdoor activities, these models offer the brightness, strength, and adaptability that users demand. Their combination of energy efficiency, smart technology, and high-quality construction makes them a leading choice in the portable lighting market.