Miele DA5960W, DA5980W, DA5990W Plywood backing, To install a plywood backing

Page 28

Plywood backing

The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage.

(If plywood backing is not needed, proceed to the included "Installation diagram".)

To install a plywood backing

￿Determine and mark the location of the retaining plate for the canopy as outlined on the "Installation diagram".

￿Make a cutting line 3" (76 mm) above and 3" (76 mm) below the outline of the retaining plate.

￿Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder.

￿Mark a vertical cutting line along the center of each stud.

￿CAUTION

When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities.

￿Remove the drywall between the cutting lines and replace it with plywood of a matching thickness (min. ½" (13 mm) thick). Tape the joints and refinish the wall.

￿Proceed to the enclosed "Installation diagram" to complete the installation.

28

Image 28 Contents
En US, CA Contents Important Safety Instructions Use To Reduce the Risk of a Cooktop Grease FireEvacuate and Call the Fire Department Installation Air extraction Recirculation mode Functional descriptionGuide to the Ventilation System Only in recirculation mode Operation Selecting the power levelTurning on the fan Fan performance Turning off the fan Automatic Safety Shut OffTurning the lighting On/Off Cleaning and Care Cleaning the casingStainless steel Stainless steel colored controlsRemoving the grease filter Cleaning the grease filter Insert the charcoal filter Changing the light bulbs Repairs After Sales ServiceMieleCare Installation Instructions Page Disposal of packing material Caring for the environmentDisposal of an old appliance Appliance dimensions For recirculation mode only 4 and only outlet installation Distance between cooktop and hood S Miele Cooktops Non-MieleAppliance dimensions Installation accessories Protective shields Vent collarReducing collar 6 locking nuts for securing the unitTo install a plywood backing Plywood backingProtective film InstallationDismantling Air extraction Condensate trap Electrical connection Grounding Instructions USA and Mexico onlyImportant USA and Mexico only Important Canada onlyTechnical data Page Page Alteration rights reserved Nr 771 660