Charcoal filter (ductless version)

This filter cannot be washed or regenerated. It must be replaced when the C appears on the display or at least once every 4 months. The filter saturation alarm has to be activated already before.

Activation of the alarm signal

In the recycling version hoods the filter saturation alarm must be activated during the instal- lation or later.

Switch off the hood and the lights.

Press the E-key for about 5 seconds until the last two segments of the motor LEDS are lit on the display.

By releasing the E-key the clock icon starts to flash.

Within 3 seconds press the D-key to activate/deactivate charcoal filter saturation alarm.

C-symbol lit - charcoal filter saturation alarm ACTIVATED.

C-symbol unlit - charcoal filter saturation alarm DEACTIVATED.

SUBSTITUTION OF THE CHARCOAL FILTER

Alarm reset

Switch off the motor and the lighting system.

Press the G-key for at least 2 seconds.

Substitution of the filter

Open the confort panel.

Remove the metal grease filters.

Remove the charcoal filter as indicated in the picture.

Place the filter again into its seat.

Place again the metal grease filters into their place.

Lighting

LIGHT REPLACEMENT

20 W halogen light.

• Remove the snap-on lamp cover by levering it from under the metal ring, supporting it with one hand.

Remove the halogen lamp from the lamp holder by pulling gently.

Replace the lamp with a new one of the same type, making sure that you insert the two pins properly into the housings on the lamp holder.

Replace the snap-on lamp cover.

EN

 

114

 

 

14

 

Image 13
Contents Kubus Index Read and Save These Instructions R N I N G R N I N G Recommendations and Suggestions InstallationUSE CareComponents DimensionsWall drilling and bracket fixing InstallationConnections Mounting the hood bodyDucted Version AIR Exhaust System Ductless Version AIR Outlet Electrical Connection Chimney assembly Upper exhaust chimney Lower exhaust chimneyControl board USERemote Control Optional Cleaning the Comfort PanelsCare Metal grease filtersCharcoal filter ductless version Light ReplacementLighting Substitution of the Charcoal FilterTable DES Matières 115 116 117 Utilisation Conseils ET SuggestionsEntretien Protecteur ThermiqueComposantes Dimensions et Principales PiècesPerçage de la paroi et fixation des brides Branchements Montage du corps de la hotteSortie D’AIR Version Aspirante Sortie D’AIR Version FiltranteBranchement Électrique Montage de la cheminéeCheminée supérieure Cheminée inférieureUtilisation Tableau de commandeSoin ET Entretien Télécommande EN OptionNettoyage des Comfort panels panneaux de confort Filtres à graisse en métalRemplacement Dune Ampoule Remplacement DU Filtre À CharbonFiltres à charbon version filtrante ÉclairagePage Page 43600389901