Sears 625.34929 owner manual RLL the Tank WroTHSOLUT, Above, the water is neutral, When feeding

Page 13

IRLL THE TANK WroTHSOLUT

1.Residual still above 0.6, and the feed control knob at 1 or 2-- Use less chlorine in the mixture For example, use 1 gallon of bleach for each 2 gallons of water instead of 1 to 1

2.Residual still below 0,2, and the feed control

knob at6or7-- Use more chlorine in the mixture

For example, use 2 gallons of bleach for each gallon of water instead of 1 to 1

WAClD WATER TREATMENT -- Remove the reser- voir (tank) cover and fill the tank with 8 gallons of WARM water. Pour in 80 oz. (10 oz per gallon of water) of Sears Neutralizing Compound, Stock No. 42-34475. Stir until the compound is completely dis- solved,

1. Plug the pump power cord in and open a nearby faucet to start the well pump, The solution pump starts to run with the well pump.

2.Turn the feed control knob (FIG, 10) to No_ 7_

3.Turn the relief-release valve (clockwise only

FIG 11) to the open position, Solution is pumped through the suction tubing, into the pump head, then returned to the tank (takes 3-5 minutes).

4.When you see solution returning to the tank (look through fill hole), close the relief-release valve turning

clockwise only. The pump head is primed and will begin to pump solution out the discharge. Replace the tank cover,,

5.When the discharge tubing is filled with solution, turn the feed control knob to No. 4 and close the faucet, opened in Step 1_

6.After 24 hours, check the pH level as follows. Adjust the feed control knob and/or the solution strength as needed.

HOW TO CHECK THE pH LEVEL (FEEDING

NEUTRALIZER COMPOUND) -- The pH level of

acid water is below 7,0 on a scale of 1 to 14, From

7,0 and above, the water is neutral, When feeding

neutralizer, it is best to keep the pH level between

7.0and80 Atestkitisincluded with yoursolution

dispensing system to make this check. After installing the system and feeding solution for 24 hours, use the test kit as follows.

1.Opena nearby faucet to start the well pump and the solution pump

2.Follow the guides with the kit to test the water from the opened faucet

3.If the pH level is below7 0, turnthe feed control

knob (FIG 10) upward slightly and check again in

24 hours If the pHchecksabove80, turnthefeed control knob downward slightly and check again in 24 hours Do this each day until thepHstays between 7.0 and 8 0 Then check every few days

NOTE: The neutralizer compound to water mix- ture ratio (10 oz. compound per gallon of water) is average You may not be able to maintaina70to

80 pH, even with the lowest or highest feed rate settings If so, do the following

1.pHabove80, and the feed control knob at 1 or2

--Use less neutralizer compound in the mixture.

For example, mix 5 oz, of neutralizer compound in each gallon of water

2. pH below7 0, andthefeedcontrolknobat6or7

--Use more neutralizer compound in the mixture, For example, mix 15 ez, of neutralizer compound in each gallon of water_

WTREATMENT OF ACID WATER THAT ALSO HAS

IRON BACTERIA, HYDROGEN SULFIDE, OR HIGH AMOUNTS OF IRON -- Begin by filling the tank with 8 gallons of WARM water, Pour in 80 oz (10 ozo per gallon of water) of Sears Neutralizer Compound, Stock No, 42-34475, Stir until the com- pound is completely dissolved. Add 2 gallons of 5.25% common household bleach (Purex, Clorox, Hilex, etc ),,

ACAUTION: ALWAYS MIX THE WATER, NEUTRAL- IZER AND BLEACH IN THE SAME ORDER AS ABOVE

1.Plug the pump power cord in and open a nearby faucet to start the well pump The solution pump starts to run with the well pump.

2.Turn the feed control knob (FIG. 10) to No. 7 -continued-

13

Image 13
Contents Model no SEAlS sOWT ONSPENS,NGSYSTEM Table of ContentsWhat does Your Solutjo Following briefly describes each of these water problemsHydrogen Sulfide Water -- Many water What Your Solut OIHas Your Water Supply had Chemical Keep a Record of Your Water System FactsPRE-TREATING Private Well Systems Treating Well WaterPUT Your Dispensing Damage From Solutions DUE to Where to Locate YourSystem where From Direct SunlightGuxdesto nNSTALL Your Pressure Tank Installed on the Main Supply LineSee page 11 to Make the Needed Elec TIP of the Injection Fitting IT is a Working PartTrical Connections Injection Fitting IT is a Working Part Solution Injection BetweenWell Pump and Pressure Tank See page 11 to Make the Needed ELEC- Trical ConnectionsWiring Diagram 230 Volt System Wiring Diagram 115 Volt SystemVolt Outlet RLL the Tank WnTH HOW to Check Chlorine ResidualIron and Hydrogen Sulfide Treatment Feed Control KnobRLL the Tank WroTHSOLUT Above, the water is neutral, When feedingWtreatment of Acid Water That Also has Fill the Tank WnTH Controls and FeaturesRELIEF-RELEASE Keep Your DaSPENSUNG Removing and Cleaning the Pump HeadSuction Valve Discharge & Return to Supply ValvesCheck the Diaphragm Keepyour DUSPENSnNGReplacing the Diaphragm Dumensbonsand Keep Your D SpensingReturn Description 818382 811704KEY Partdescription 811703 8800418 14 L98013-188 16 U0816093 8800710AI S