Scotsman Ice CU50 service manual Cube Size Adjustment, Cube Size Change Table

Page 11

CU50

Service Manual

Cube Size Adjustment

The cube size can be adjusted by changing the amount of freeze cycle time. This is done by a button press sequence.

Note: There is only one correct cube size. See the illustrations.

To adjust cube size:

1.Shut the machine off: If it's off on bin full press and release the On/Off button once, switching the Ice Making light off. If the machine is making ice hold the On/Off button in until the Ice Making light is off.

2.Press and hold the Clean button for 5 seconds (light on), then release (light out)

Side Views of Cubes

Too Small, Adjust Cycle Longer

3. View the lights. Compare to the table below.

Cube Size Change Table

 

On/Off

Water

Clean

Default

off

off

off

Add 1 minute

on

off

off

Add 2 minutes

off

on

off

Add 3 minutes

off

off

on

Add 4 minutes

on

on

on

- 1 minute

flash

off

off

- 2 minutes

off

flash

off

- 3 minutes

off

off

flash

- 4 minutes

flash

flash

flash

4.Select the amount of change.

5.Push and release the On/Off button until the correct light pattern is displayed.

6.Push and release the Clean button to select that setting.

Just Right

Too Large, Adjust Cycle Shorter

7. Push and release On/Off to return to ice making.

March 2010

Page 11

Image 11 Contents
Introduction Table of ContentsSpecifications Cabinet Layout PowercordAir flow Filters and Treatment Installation OverviewWater Quality Door swing change Installation Notes Drain Pump Model drain installation Installation Water & DrainGravity Drain Initial Start Up Installation check listElectrical Cube Size Change Table Cube Size AdjustmentHarvest Time Table Harvest Time AdjustmentReset time to clean indicator light Control SettingsAutomatic water purge enable / disable Use Condenser cleaning How to clean the condenser and winterizeHow to remove scale from the ice making system Bin control System InformationElectrical Sequence Electrical ComponentsWater System Components Maximum Harvest Time minutes ControllerPerformance Information Discharge Pressure Refrigeration SystemTime Deg. F · Ohms Deg. F. · Ohms Thermistor ValuesProblem Likely Cause Probable Solution Service DiagnosisMakes excessive noise Removal and Repair Transformer Evaporator ThermistorController Control PanelRemoval and Repair Cabinet Removal CU50 Refrigeration Service