Sears 8101 P590-60 Gas Conversion, General, Appliance Pressure Regulator Conversion

Page 7

Gas Conversion

General

All ovens are equipped with double coaxial (universal) orifices and with a convertible appliance pressure regulator. The unit model number plate states which gas it was adjusted for at the factory. To convert the unit to either Natural gas or LP gas will require adjustment of the orifice hood and air shutter on the burner and adjustment of the appliance pressure regulator converter cap.

Inlet pressure to the appliance pressure regulator should be as follows for both operation and checking of appliance pressure regulator setting:

INLET PRESSURE IN

NATURAL

LP

INCHES OF WATER COLUMN

GAS

GAS

Minimum

5

11

Maximum

14

14

off with nut). "IMPORTANT" remove plastic dust cover from cap nut and reinstall on opposite side of cap nut.

Reinstall cap nut to appliance pressure regulator and replace dust cover. "CAUTION" be sure marking for the type of gas to which appliance pressure regulator has just been converted is visible in top of cap nut before replacing plastic dust cover. (See figure 7.)

. Remove cap and forcibly snap out plastic plunger from bottom of cap. Turn plunger over and forcibly snap back in original location (figure 8).

NOTE: PLUNGER MUST SNAP INTO POSITION; THE GAS TYPE YOU ARE CONVERTING TO MUST BE VISIBLE ON LOWER SIDE OF PLUNGER.

Appliance Pressure Regulator Conversion

The unit appliance pressure regulator must be set to match the type gas supply used. If converting from natural gas to LP gas, the appliance pressure regulator must be converted to regulate LP gas. If converting from LP gas to natural gas, the appliance pressure regulator must be converted to regulate natural gas.

TO CONVERT THE APPLIANCE PRESSURE REGULATOR FROM ONE GAS TO ANOTHER, DO EITHER (1), (2) OR (3) BELOW: YOUR UNIT WILL BE EQUIPPED WITH ONE OF THE THREE APPLIANCE PRESSURE REGULATOR TYPES SHOWN BELOW.

1.Remove the cap, push down and turn counter-clockwise. Turn the cap over and reinstall (figure 6).

NOTE: THE GAS TYPE YOU ARE CONVERTING TO MUST BE VISIBLE ON THE TOP OF THE INSTALLED APPLIANCE PRESSURE REGULATOR CAP.

2.Remove plastic dust cover from cap nut on top of

appliance pressure regulator. Remove cap nut from appliance pressure regulator (plastic dust cover comes

OO_ f_(

_ONAT

LPG C

Checking Manifold Gas Pressure

BUILT-IN OVENS:

On built-in ovens, remove 1/8 inch pipe plug from front or side of gas pressure regulator, install 1/8" "B" valve, 1/8 inch piece of pipe, connect manometer, make sure main burner is on to obtain accurate pressure check.

Be sure the gas supply (house piping) pressure is at least one inch (1 ") above specified range manifold pressure. The gas supply pressure should never be over fourteen inches (14") water column.

Checking Pressure Of House Piping System

The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 Ibs./sq. in. (13.8 in. W.C.).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping

system at test pressures equal to or less than 1/2 Ibs./sq. in. (13.8 in. W.C.).

L.P. POSITION

,/

 

ART _ A219-740

 

 

OVEN MANIFOLD GAS _

j_

 

FOR SOME OVEN

 

PRESSURETAP

MODELS

FIGURE 6

FIGURE 7

FIGURE 8

-7-

Image 7
Contents 8101 P590-60 Please Keep this Manual for Future ReferenceDoubl GAS Wall OvensFloc HeightInstallation Gas Supply Connecting The OvenCommonwealth Of Massachusetts Wall Oven Adjustment Unit AdjustmentsElectric Ignition Bake Burner with Electric Glow BAR Flame Lock Screw AIR Shutter Orifice HO High Altitude NoticeAIR Shutter Oven Burner Burner BaffleChecking Manifold Gas Pressure Gas ConversionGeneral Appliance Pressure Regulator ConversionFrom Natural GAS to LP/PROPANE GAS Orifice ConversionFrom LP/PROPANE GAS to Natural GAS