Mechanical Specification

Trane Adaptive FrequencyDrive (AFD)

The Trane AFD is a closed-loop, liquid- cooled, microprocessor based PWM design that converts fixed utility voltage and frequency to a variable voltage and frequency via a two-step operation. The AFD is both voltage and current regulated. Output power devices: IGBT transistors.

The AFD is factory mounted on the chiller and ships completely assembled, wired and tested.

Patented Trane AFD control logic is specifically designed to interface with the centrifugal water chiller controls. AFD control adapts to the operating ranges and specific characteristics of the chiller, and chiller efficiency is optimized by coordinating compressor motor speed and compressor inlet guide vane position. Chilled water control and AFD control work together to maintain the chilled water setpoint, improve efficiency and avoid surge. If a surge is detected, AFD surge avoidance logic will make adjustments to move away from and avoid surge at similar conditions in the future.

AFD is capable of operating at an altitude of 3300 feet rated output current. For every 300 feet above 3300 feet, the rated output current will be decreased by 1%.

AFD Design Features

NEMA 1 ventilated enclosure with a hinged, locking door and door- mounted circuit breaker with shunt trip, is tested to a short circuit withstand rating of 65,000 amps per UL 508. The entire package is UL/CUL listed.

Digital keypad displays DC bus voltage, drive output motor current; output frequency (Hz); RPM; kW; percent motor torque; and elapsed time. LED’s also display drive status: running, remote, jog, auto, forward, reverse or program.

One programmable analog output signal, (0-10 Vdc or 4-20 mA) for customer use.

Three programmable relay outputs for customer use.

Simple modular construction.

The drive is rated for 480/60/3 input power, +/-10%, with a motor thermal overload capability of 110% continuous for 25 minutes to 150% for 60 seconds, linear between 110 and 150.

Input displacement power factor will exceed .96 regardless of speed and load.

Minimum efficiency of 97% at rated load and 60 hertz.

Soft-start; linear acceleration/coast to stop.

Standard DC bus filter choke to limit harmonic distortion.

All control circuit voltages are physically and electrically isolated from power circuit voltage.

150% instantaneous torque available for improved surge control.

Critical frequency avoidance.

Output line-to-line and line-to-ground short circuit protection.

Restart into a rotating motor.

AFD can be started without a motor connected.

Chiller Unit Control Features for AFD The chiller unit control panel standard control capabilities provide for the control/configuration interface to, and the retrieval/display of the collaterally additional AFD related data. AFD standard design features controlled through the starter module of UCP2 include:

Current limited to 100%.

Auto restart after an interruption of power limited to four starts per hour, 30 seconds between starts.

Output speed reference signal 2-10 vdc.

Digital display on UCP2 panel: output speed in hertz, output speed in rpm, fault, amps, input line voltage.

Motor overload protection.

Loss of follower signal – in the event of loss of input speed signal the AFD will default to 38 hertz or hold speed based on last reference received.

Phase loss, reversal, imbalance protection.

Power loss ride through.

Overvoltage/undervoltage protection.

Motor overtemperature protection.

Environmental ratings:

32°F to 104°F (0°C to 40°F) operating temperature

Altitude to 3300 feet (1000 m)

Humidity, 95% non-condensing

Input Line Reactor Option

Field installed option mounts on the input side of the AFD to reduce harmonic distortion and help meet IEEE-519 guidelines. NEMA 1 enclosure; 5% impedance.

CTV-PRC007-EN

51

Image 51
Contents CenTraVac Liquid Chillers Emissions Chiller IntroductionWorld’s Most Efficient LowestContents Tradition of Innovation Trane HermeticCentrifugal Water ChillersLhcv CenTraVac Modular Chiller system IntroductionLow Pressure FeaturesBenefits AttributesCapabilities include ControlPanel Operator Control PanelBenefits Components FeaturesStandard Features and and Optional Benefits FeaturesStandard Features Optional FeaturesFeatures and Performance Benefits Testing Factory Testing for Assured PerformanceFactory Refrigeration CycleCenTraVac Chiller Operating Cycle Two-Stage CenTraVac P-H Diagram Starter UnitOptions Unit MountedFeatures ReliabilityOperation Integral Bypass Contactors Available options includeLarge number of part-load operating hours annually AdaptiveFrequency Drives BenefitsHigh kW Charges Condenser water temperature relief of chilled water resetEase of Operation Ease of InstallationUnit Free CoolingFigure O-5 Compressor Operation Schematic Auxiliary Condenser System Auxiliary Options CondenserControls SystemAuxiliary CondenserIce Storage SystemSystem Options Heat RecoverySystem Design Considerations Heat RecoveryCont Simultaneous Heating and CoolingReset Chilled Water Reset Chilled waterChilled Water Application ConsiderationsFor Applications Requiring Tons 60 Hz Choose Lhcv Electrical Information Condenser Water LimitationsSelection Procedure Roughing-in Dimensions Part Load PerformanceEvaporator and Condenser Data Tables Flow Rates PerformanceData EvaporatorMinimum/Maximum Condenser Flow Rates GPM Supply and Motor Lead Wiring and Connections Shipment and AssemblyJobsite Connections Controls Advanced ControlsSystems Performance Controls Control Chiller PlantBuilding Automation and Chiller Plant Control Functions Controls Protections Control FunctionsMachine Protections Functions Controls Diagnostics Modules ControlsModules/Sequence OperationUnit is Running Capacity Limited by High Current Hz Compressors WeightsCvhg Dimensions PhysicalEnglish Units SI Units ML &LL 10630 3867 4080 4724 1327 4578 2908 2419 2632 Waterbox Physical Connection Dimensions ArrangementWaterbox Lengths English Units Physical DimensionsWaterbox Lengths Metric Units Mechanical Specification CompressorEvaporator Unit Control Panel Condenser/Heat Recovery CondenserEconomizer Purge SystemInsulation Isolation PadsRefrigerant and Oil Charge Thermometer Wells and Sight GlassesInput Line Reactor Option AFD Design FeaturesTrane Adaptive Frequency Drive AFD Environmental ratingsTrane Company is a participant in the Green Seal Program

ctv-prc007-en specifications

The Trane CTV-PRC007-EN is an advanced air conditioning unit that epitomizes efficiency and reliability in temperature control. Designed for commercial and industrial applications, this unit stands out with a multitude of features aimed at enhancing performance, energy savings, and sustainability.

One of the key characteristics of the CTV-PRC007-EN is its high cooling and heating capacities, allowing it to cater to a variety of environments. The unit utilizes a scroll compressor, known for its energy efficiency and durable design, which contributes to substantial energy savings over time. The inclusion of variable speed technology further optimizes energy use by adjusting to the specific cooling or heating demands of the space.

Equipped with Trane’s proprietary Sintesis technology, the CTV-PRC007-EN offers superior temperature control while minimizing noise levels. This feature makes it ideal for settings where quiet operation is essential, such as offices, hotels, and conference rooms. The unit’s sound-dampening design reduces operational noise, ensuring a comfortable environment for occupants.

Another significant advantage of the CTV-PRC007-EN is its advanced control system. The integration of Smart Temperature Management allows for precise monitoring and adjustment, enhancing the overall user experience. Additionally, the system is compatible with various building management systems, enabling remote monitoring and control, which can significantly reduce operational costs and improve efficiency.

The CTV-PRC007-EN also embraces eco-friendly refrigerants, aligning with global sustainability goals. By using refrigerants with low global warming potential, Trane demonstrates its commitment to reducing environmental impact while maintaining high performance.

Maintenance is straightforward with the CTV-PRC007-EN. The unit's robust design includes accessible components that simplify servicing, helping to minimize downtime and operational costs. It comes with a comprehensive warranty, underscoring Trane’s confidence in the durability and reliability of its products.

In conclusion, the Trane CTV-PRC007-EN stands as a testament to cutting-edge technology in HVAC solutions. With its energy efficiency, advanced control systems, quiet operation, and eco-friendly features, it is an ideal choice for businesses seeking effective climate control solutions that do not compromise on sustainability or performance.