Trane CVGF manual Physical, Dimensions

Page 18

Physical

50 and 60 Hz SI

Dimensions

(English Units)

 

 

 

 

Figure PD-1 – Model CVGF Cooling Only

Figure PD-2 – Model CVGF Cooling Only Without Unit

With Unit Mounted Starter

Mounted Starter (for Remote Mounted Starter)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

914 mm (36)

 

 

914 mm (36)

 

 

 

RECOMMENDED

 

 

RECOMMENDED

 

 

 

CLEARANCE

 

 

CLEARANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEIGHT

HEIGHT

WIDTH

WIDTH

457 mm (18')

RECOMMENDED

CLEARANCE

LENGTH

Dimensions – SI Units (English Units)

 

 

Clearance

 

Unit Dimensions

 

Unit Dimensions

 

 

Tube Pull

 

With Unit Mounted Starters

 

Without Unit Mounted Starters

Comp.

Shell Size

CL1

CL2

Length

Height

Width

Width

400-500

500

4235 mm

1118 mm

4083 mm

2094 mm

1984 mm

1929 mm

 

 

(13’ 10 3/4”)

(3’ 8”)

(13’ 4 3/4”)

(6’ 101/2”)

(6’ 6 1/8”)

(6’ 3 15/16”)

500

700

4235 mm

1850 mm

4083 mm

2200 mm

2038 mm

1988 mm

 

 

(13’ 10 3/4”)

(3’ 11”)

(13’ 4 3/4”)

(7’ 2 5/8”)

(6’ 8 1/4”)

(6’ 6 1/4”)

650

700

4235 mm

1850 mm

4083 mm

2270 mm

2083 mm

2076 mm

 

 

(13’ 10 3/4”)

(3’ 11”)

(13’ 4 3/4”)

(7’ 5 3/8”)

(6’ 10”)

(6’ 9 3/4”)

800-1000

1000

4235 mm

1219 mm

4083 mm

2521 mm

2305 mm

2257 mm

 

 

(13’ 10 3/4”)

(4’)

(13’ 4 3/4”)

(8’3 1/4”)

(7’6 3/4”)

(7’ 4 7/8”)

CL1 at either end of machine and is required for tube pull clearance.

CL2 is always at the opposite end of machine from CL1 and is for water box plus clearance.

Recommended clearance (D1) for machine with unit mounted starter is 914 mm (36”)

Recommended clearance (D2) for machine without unit mounted starter is 1219 mm (38”) Unit length is not included for the waterbox.

See page 19 for waterbox dimension

1 8

CTV-PRC001-GB

 

Image 18
Contents Centrifugal Water Chillers Introduction IntroductionContents Environmental Features and Benefits Features and BenefitsStandard Cvgf Features Additional Features and BenefitsMicroprocessor Controls with CH530 DynaView Operator InterfaceServiceability TechViewFeedforward Adaptive Control Soft LoadingFast Restart Chiller-Tower Optimization Why Centrifugal Compressors Surge Two-Stage Compressor Widens the Application RangeTwo-Stage Compressors Surge Less and Later Water Pumps TemperatureCondenser Water Limitations Water FlowGeneral Data Table GD-1 Model Cvgf DescriptionGeneral English UnitsShipment and Assembly Jobsite ConnectionsHeat Exchanger Control Standard FeaturesField Connection Motor Control and Compressor ProtectionBase-Loading Control Controls FeaturesExtended Operation Package Hot-Water ControlTracer Chiller Controller Oil-Temperature ProtectionPhase-Loss Protection Loss of Water-Flow ProtectionCurrent Overload Protection Momentary Power LossHigh Motor-Winding Temperature Protection Surge Detection ProtectionDimensions PhysicalPhysical Dimensions Model Cvgf Water Connection Pipe SizeMechanical Specifications Unit Control Panel Painting Isolation PadsRefrigerant and Oil Charge InsulationLength Energy and Power and Capaclty ConversionServicing of equipment referred to in this publication
Related manuals
Manual 28 pages 34 b

CVGF specifications

The Trane CVGF series is a revolutionary innovation in the world of commercial HVAC systems, designed to deliver unparalleled performance and energy efficiency. This air-cooled chiller line is specifically engineered to meet the demands of modern buildings, making it an ideal choice for various applications such as offices, hospitals, and educational institutions.

One of the standout features of the CVGF series is its use of the Trane Adaptive Control technology. This advancement provides the system with real-time data analytics, allowing it to automatically adjust cooling output based on environmental conditions and load requirements. This level of adaptability not only enhances occupant comfort but also contributes to significant energy savings, aligning with sustainability goals.

The CVGF chillers also incorporate a robust and efficient scroll compressor, which operates quietly and minimizes vibration. This design choice ensures reliability and longevity while reducing operational noise levels, making it suitable for installations in noise-sensitive environments. Furthermore, the scroll compressor's efficiency plays a crucial role in achieving a higher coefficient of performance (COP), which translates to lower energy costs.

In terms of environmental responsibility, the CVGF series is designed with an eco-friendly refrigerant that supports lower global warming potential (GWP). Committed to sustainability, Trane ensures that these chillers not only meet but exceed regulatory requirements, allowing businesses to operate with a reduced carbon footprint.

Another remarkable characteristic of the CVGF line is its modular design, which simplifies installation and maintenance. The units are compact and can be easily integrated into existing infrastructure, minimizing disruption during upgrades or replacements. The straightforward maintenance protocols further enhance the system’s uptime, ensuring users enjoy consistent and reliable cooling performance.

Moreover, the CVGF chillers are equipped with advanced monitoring capabilities, accessible through Trane’s proprietary software. This feature enables facility managers to oversee system performance from any location, facilitating proactive adjustments and timely maintenance interventions.

Overall, the Trane CVGF series stands out as a cutting-edge solution for effective and sustainable cooling in commercial applications. By combining innovative technologies, energy-efficient design, and user-friendly features, the CVGF offers a comprehensive approach to achieving optimal climate control while meeting the challenges of the future.