Introducing Trane’s Model CVGF Centrifugal Water Chiller

Introduction

The basic gear driven centrifugal water chiller design was introduced in 1976 and has been proven in thousands of installations. The Trane Company continues to deliver its reliability and energy fitness commitment on its newest line of gear drive centrifugal water chillers, the Model CVGF.The major advantages of the Model CVGF are:

High reliability

Low sound levels

Compact size

High efficiency at a competitive market price

Designed to use environmentally responsible HFC-134a refrigerant.

The Model CVGF chiller is ideal for office, hospital, school, hotel, retail store and industrial buildings. The Trane centrifugal chiller line offers hundreds of individual evaporator- condenser-compressor combination selections, permitting precise tailoring of the machine capacity to system requirements. Machine selections can be computer optimized to provide low first cost, low operating cost or other criteria important for a particular selection. Centrifugal Water Chiller computer selection program is certified in accordance with ARI standard 550/

590.Trane Sales Engineers are available to assist in selecting the optimum machine to satisfy the particular project requirements.

Turn to the Model CVGF for energy efficiency provided by the two stage gear drive centrifugal water chillers with economizers. The Trane Model CVGF is your choice for energy fit operation year after year.

© 2004 American Standard Inc. All rights reserved.

CTV-PRC001-GB

Image 2
Contents Centrifugal Water Chillers Introduction IntroductionContents Environmental Features and Benefits Features and BenefitsStandard Cvgf Features Additional Features and BenefitsMicroprocessor Controls with CH530 DynaView Operator InterfaceServiceability TechViewFast Restart Feedforward Adaptive ControlSoft Loading Chiller-Tower Optimization Two-Stage Compressors Surge Less and Later Why Centrifugal Compressors SurgeTwo-Stage Compressor Widens the Application Range Water Pumps TemperatureCondenser Water Limitations Water FlowGeneral Data Table GD-1 Model Cvgf DescriptionGeneral English UnitsShipment and Assembly Jobsite ConnectionsHeat Exchanger Control Standard FeaturesField Connection Motor Control and Compressor ProtectionBase-Loading Control Controls FeaturesExtended Operation Package Hot-Water ControlTracer Chiller Controller Oil-Temperature ProtectionPhase-Loss Protection Loss of Water-Flow ProtectionCurrent Overload Protection Momentary Power LossHigh Motor-Winding Temperature Protection Surge Detection ProtectionDimensions PhysicalPhysical Dimensions Model Cvgf Water Connection Pipe SizeMechanical Specifications Unit Control Panel Painting Isolation PadsRefrigerant and Oil Charge InsulationLength Energy and Power and Capaclty ConversionServicing of equipment referred to in this publication
Related manuals
Manual 28 pages 34 b

CVGF specifications

The Trane CVGF series is a revolutionary innovation in the world of commercial HVAC systems, designed to deliver unparalleled performance and energy efficiency. This air-cooled chiller line is specifically engineered to meet the demands of modern buildings, making it an ideal choice for various applications such as offices, hospitals, and educational institutions.

One of the standout features of the CVGF series is its use of the Trane Adaptive Control technology. This advancement provides the system with real-time data analytics, allowing it to automatically adjust cooling output based on environmental conditions and load requirements. This level of adaptability not only enhances occupant comfort but also contributes to significant energy savings, aligning with sustainability goals.

The CVGF chillers also incorporate a robust and efficient scroll compressor, which operates quietly and minimizes vibration. This design choice ensures reliability and longevity while reducing operational noise levels, making it suitable for installations in noise-sensitive environments. Furthermore, the scroll compressor's efficiency plays a crucial role in achieving a higher coefficient of performance (COP), which translates to lower energy costs.

In terms of environmental responsibility, the CVGF series is designed with an eco-friendly refrigerant that supports lower global warming potential (GWP). Committed to sustainability, Trane ensures that these chillers not only meet but exceed regulatory requirements, allowing businesses to operate with a reduced carbon footprint.

Another remarkable characteristic of the CVGF line is its modular design, which simplifies installation and maintenance. The units are compact and can be easily integrated into existing infrastructure, minimizing disruption during upgrades or replacements. The straightforward maintenance protocols further enhance the system’s uptime, ensuring users enjoy consistent and reliable cooling performance.

Moreover, the CVGF chillers are equipped with advanced monitoring capabilities, accessible through Trane’s proprietary software. This feature enables facility managers to oversee system performance from any location, facilitating proactive adjustments and timely maintenance interventions.

Overall, the Trane CVGF series stands out as a cutting-edge solution for effective and sustainable cooling in commercial applications. By combining innovative technologies, energy-efficient design, and user-friendly features, the CVGF offers a comprehensive approach to achieving optimal climate control while meeting the challenges of the future.