GE CV936 manual Install Hood Support, Install Transition, Install Hood Onto Wall

Page 14

Installation Instructions

1INSTALL HOOD SUPPORT

IMPORTANT: Framing must be capable of supporting 100 lbs (45.3 kg)

Locate at least 2 vertical studs at the wood mounting location by tapping drywall with a hammer or use a stud finder.

Center the supplied wood horizontal support, left to right and below the marked line.

7” Min. Opening for Ductwork

 

Wood

15-3/8"

Support

 

24"

to

36"

Centerline of Installation space

Drill 1/8” pilot holes through the support, drywall and into the studs. Secure the support to 2 or morevertical studs with supplied wood screws.

IMPORTANT: Screws must penetrate at least 1½” into vertical studs. Countersink screws into support.

13-1/16"

¼” Gap

Install mounting screws in the center of the wood support, 13-1/16” from the centerline. The screws should protrude forward ¼”. This ¼” gap will provide clearance to hang the hood.

2INSTALL TRANSITION

IMPORTANT: Remove

Remove

Shipping

shipping tape from

Tape on

damper and check that

Damper

damper moves freely.

 

Duct

Top of

Transition

Hood

Place the transition piece over the hood exhaust. Secure transition to hood with 4 screws provided.

Use duct tape to seal the connection.

3INSTALL HOOD ONTO WALL

Lift the hood and place over the wood support. The top keyhole slots in the hood should engage the protruding mounting screws. Allow the hood to slide down into position.

Pull house wiring through knockout at the rear or the top of the hood.

Check to be sure the hood is level and centered. The arrow shaped cutout in the back of the hood allows viewing the marked centerline.

Remove cover from junction box.

Cutout

24"

Centerline of

to

Installation

36"

space

 

 

 

 

 

 

 

 

 

 

 

 

Drill Bottom Mounting Hole Locations

Drill 1/8” pilot holes into the two lower mounting holes. Enlarge the holes if they did not enter studs to 3/8”.Tap anchors for wall fasteners into bottom holes.

Install screws by hand into the fasteners to allow anchors to expand against the wall. Remove screws.

Using two large flat washers (supplied), install wood screws or wall fastener screws, loosely, into lower mounting holes. Do not tighten.

Check hood level. Tighten upper screws. Tighten lower mounting screws.

For additional security, drive screws through the original wood support screw holes in the back of the hood.

1 Ft = 0.3 m; 1” = 2.5 cm

14

Image 14
Contents Range Hoods Safety Precautions Read and Save These Instructions Light Control Using the hood controlsFAN Control Stainless Steel Surfaces on some models Care and cleaning of the vent hoodPainted Surfaces on some models Hood Lights To removeFt = 0.3 m 1 = 2.5 cm Product DimensionsRead these instructions completely and carefully Duct Cover Installation ClearancesOptional Accessories Commercial Filter KitDuct Fittings Power SupplyAdvance Planning Decorative Duct CoversDuct. It Can Transition To ¼ x 12 Duct Kit JXDW1 Flexible ductingTools and Materials Required Remove the PackagingParts Provided Duct Cover RequirementsTo route house wiring through the wall Determine HOOD, Ductwork and Wiring LocationsTo route house wiring through the ceiling or soffit For Vertical Straight Up DuctingInstall Hood Onto Wall Install Hood SupportInstall Transition Drill Bottom Mounting Hole LocationsInstall Hood to Soffit or Beneath Cabinets Skip this Step if Using Wall Mounting MethodInstall Ceiling Bracket Connect DuctworkInstall Filter Support Install MotorInstall Duct Covers Connect ElectricalInstall Control Knobs Install Filters11A Install Optional Commercial Filters Finalize InstallationPage Before you call for service… Excessively soiled filtersOwnership Registration For Canadian Customers Pour les consommateurs canadiens What Mabe Will Not Cover Range Hood WarrantyMabe Will Replace Consumer Support GE Appliances Website Schedule ServiceParts and Accessories Extended Warranties

CV936 specifications

The GE CV936 is a versatile and powerful gas turbine designed for use in a variety of industrial and power generation applications. With its advanced design and state-of-the-art technologies, the CV936 represents a significant step forward in the field of aeroderivative gas turbines.

One of the standout features of the GE CV936 is its impressive efficiency. This turbine achieves a fuel efficiency rate that allows operators to maximize output while minimizing fuel consumption, thereby reducing overall operating costs. The efficiency extends beyond fuel usage, contributing to lower emissions as the turbine is designed to comply with rigorous environmental regulations.

The CV936 incorporates advanced aerodynamics in its design. Its blades are engineered using sophisticated computer modeling techniques that enhance airflow and optimize performance. The materials chosen for these components are lightweight yet durable, which contributes to the turbine’s ability to operate at high temperatures without degradation in performance.

A significant technology aspect of the GE CV936 is its modular design. This feature not only simplifies maintenance but also allows for quick and efficient upgrades as technology evolves. Operators can benefit from improved performance without needing to replace the entire turbine, which can be a cost-effective solution for many businesses.

Another characteristic that sets the CV936 apart is its robust control system. Coupled with advanced sensors and data analytics capabilities, the turbine provides real-time monitoring and operational insights. This allows for proactive maintenance strategies, reducing downtime and extending the operational lifespan of the equipment.

The turbine's design also accommodates a wide variety of fuels, making it exceptionally flexible for different operational contexts. Whether used in simple cycle, combined cycle, or cogeneration setups, the CV936 can efficiently use natural gas and liquid fuels, giving operators the flexibility to adapt to their specific energy needs.

In summary, the GE CV936 gas turbine is a cutting-edge solution that combines high efficiency, advanced aerodynamics, modular design, and robust control technologies. Its ability to adapt to various fuel types and configurations makes it an excellent choice for companies looking to optimize their power generation capabilities while minimizing environmental impact.