IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING

SAFETY PRECAUTIONS

WARNING³725('8&(7+(5,6.2) ),5((/(&75,&6+2&.25,1-85<723(56216

OBSERVE THE FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched

on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

C. Do not use this unit with any solid-state speed- control device.

D. This unit must be grounded.

CAUTION³)25*(1(5$/9(17,/$7,1*

USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.

WARNING³725('8&(7+(5,6.2) ,1-85<723(56216,17+((9(172)$5$1*(

TOP GREASE FIRE, OBSERVE THE FOLLOWING*:

A.SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

B.1(9(53,&.83$)/$0,1*3$1³<RXPD\EH burned.

C. DO NOT USE WATER, including wet dishcloths or

WRZHOV³DYLROHQWVWHDPH[SORVLRQZLOOUHVXOW

D. Use an extinguisher ONLY if:

1.You know you have a Class ABC extinguisher, and you already know how to operate it.

2.The fire is small and contained in the area where it started.

3.The fire department is being called.

4.You can fight the fire with your back to an exit.

*Based on “Kitchen Fire safety Tips” published by NFPA.

WARNING³725('8&(7+(5,6.2)

A RANGE TOP GREASE FIRE:

A. Never leave surface units unattended at high or medium settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

B. Always turn hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

C. Clean ventilating fans frequently. Grease should

not be allowed to accumulate on fan or filter.

D. Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING³725('8&(7+(5,6.2) ),5((/(&75,&6+2&.25,1-85<723(56216

OBSERVE THE FOLLOWING:

A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire- related construction.

B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting.

Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions.

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.

WARNING³725('8&(7+(5,6.2)

FIRE, USE ONLY METAL .

‡'RQRWDWWHPSWWRUHSDLURUUHSODFHDQ\SDUWRI your hood unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician.

READ AND SAVE THESE INSTRUCTIONS.

3

Image 3
Contents ZV950 ZV1050 Owner’s ManualBefore using your stainless steel hood ContentsWrite down the model Serial numbers FIRE, USE only Metal Observe the FollowingTOP Grease FIRE, Observe the Following Range TOP Grease FireVapeurs Explosives Réduire LE Risque D’INCENDIE, DE SecousseÉlectrique OU DE Blessure , Observez LES Précautions SuivantesControls Controls and FeaturesHood surfaces Care and CleaningFor your safety Pour votre securité Metal grease filter Clean filter lightTo change the light bulbs Light bulbsProblem Possible Cause Use this problem solver Problem SolverL4Y 4G1 BOXPage 800.626.2000 Consumer ServicesDUUDQWRU*HQHUDOOHFWULF&RPSDQ\/RXLVYLOOH. WarrantyLimited ONE-YEAR Warranty ‡DPDJHFDXVHGDIWHUGHOLYHU\ ‡,PSURSHULQVWDOODWLRQ
Related manuals
Manual 12 pages 30.1 Kb

ZV950, ZV1050 specifications

The GE ZV950 and ZV1050 are advanced digital microprocessor-based relay protection devices designed for various applications in electrical utilities and industrial facilities. These devices are engineered to enhance system reliability and safety by providing accurate monitoring, protection, and control of electrical systems.

The GE ZV950 is specifically tailored for overhead line protection and transformer applications. It features multiple protection functions including overcurrent, earth fault, and distance protection. The relay is equipped with real-time measurements and advanced fault detection capabilities that significantly reduce outage durations. Its ergonomic design facilitates easy installation and integration into existing systems, allowing for seamless upgrades and enhancements.

On the other hand, the GE ZV1050 is a versatile protection relay designed for a broader range of applications. It boasts enhanced features such as differential protection, which is crucial for identifying discrepancies in current between the input and output terminals, thereby preventing severe equipment damage. Additionally, the ZV1050 supports a wide range of communication protocols, including IEC 61850, which allows for interoperability with a variety of devices and systems, making it an ideal choice for modern smart grid applications.

Both models utilize cutting-edge technologies, including digital signal processing and advanced algorithms for fault detection and diagnosis. This ensures that operational data are processed and analyzed efficiently, providing operators with timely information to make informed decisions. The relays also come equipped with comprehensive event logging and fault analysis capabilities, enabling thorough investigative processes following any disturbances.

In terms of characteristics, both ZV950 and ZV1050 relays are designed to withstand harsh environmental conditions, ensuring reliability in outdoor and industrial settings. They feature robust enclosures that protect against dust, moisture, and mechanical impacts, while also maintaining adherence to industry standards for safety and performance.

Overall, the GE ZV950 and ZV1050 represent the next generation of protection relays, equipped with features and technologies that not only enhance operational efficiency but also contribute to the longevity of electrical infrastructure. By integrating these cutting-edge devices into their systems, utilities and industries can achieve a more reliable and resilient electric grid.