GE JVM1750SMSS dimensions Following carefully, Duct Equivalent Feet

Page 2

JVM1750SMSS

GE Spacemaker® Over-the-Range Microwave Oven

Dimensions and Installation Information (in inches)

 

Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the

Optional Accessories (Available at additional cost)

following carefully.

 

Exhaust Connection: The hood exhaust has been designed to mate with a standard

3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct

Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.

Maximum Duct Length: For satisfactory air movement, the total duct length of

3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 120 equivalent feet.

Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.

Duct

Equivalent Feet

A. Rectangular-To-round

 

Transition Adaptor

5 ft.

 

 

B. Wall Cap

40 ft.

 

 

C. 90° Elbow

10 ft.

 

 

D. 45° Elbow

5 ft.

 

 

E. 90° Elbow

25 ft.

 

 

F. 45° Elbow

5 ft.

 

 

G. Roof Cap

24 ft.

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

12" Filler Panel Kits

JX41–Black

JX40WH–White

15" Filler Panel Kits

JX48BL–Black

JX48WH–White

When replacing a 36" or

42" range hood, this kit fills in the additional width to

provide a custom built-in appearance. For installation between cabinets only; not

for end-of-cabinet installation. Each kit contains two 3"-wide filler panels.

Filter KitsJX81– Recirculating Charcoal Filter KitTo be used when the Spacemaker microwave oven cannot be vented to the outside.

Listed by

Underwriters

Laboratories

Specification Revised 8/07

340121

Image 2