GE SCB2000, SCB2001 owner manual Advantium Quick Start, Set the clock, Begin speedcooking

Page 10

Advantium Quick Start

Advantium Oven

Set the clock

SPEED

POWER

TIMER

MICRO

 

COOK

LEVEL

WAVE

 

REPEAT LAST

 

 

 

OVEN LIGHT

 

BACK

MANUAL

OPTIONS

HELP

MICRO

 

COOK

EXPRESS

 

 

 

 

 

 

 

RECIPE

 

 

 

 

 

 

Begin speedcooking

RN

TOS

ELEC

TU

T

P

TER

R

ESS TOEN

START

PAUSE

CLEAR

OFF

When you first plug in the oven or after a power outage:

1.Turn the selector dial to set

the hour. Press the dial to enter.

2.Turn the dial to set the minute. Press the dial to enter.

3.Turn the dial to select AM or PM. Press the dial to enter.

To change the time:

1.Press the OPTIONS button.

2.Turn the dial to CLOCK.

Press the dial to enter and follow the display directions to set.

SPEED

POWER

TIMER

MICRO

 

COOK

LEVEL

WAVE

 

REPEAT LAST

 

 

 

OVEN LIGHT

 

BACK

MANUAL

OPTIONS

HELP

MICRO

 

COOK

EXPRESS

 

RECIPE

 

 

 

 

 

 

 

 

 

Step 1:

TU

O

T

PAUSEPress the SPEEDCOOK button.

 

NT

SEL

START

R

EC

 

 

 

CLEAR

P

 

TER

OFF

R

 

 

ESS TOEN

 

The oven rack (turntable)

SPEED

POWER

TIMER

MICRO

 

COOK

LEVEL

WAVE

 

REPEAT LAST

 

 

OVEN LIGHT

BACK

MANUAL

OPTIONS

HELP

MICRO

 

COOK

EXPRESS

 

RECIPE

 

 

 

 

SPEED

POWER

TIMER

MICRO

 

COOK

LEVEL

WAVE

 

REPEAT LAST

 

 

OVEN LIGHT

BACK

MANUAL

OPTIONS

HELP

MICRO

 

COOK

EXPRESS

 

RECIPE

 

 

 

 

NTOSEL

START

UR

ECT

T

 

PAUSE

 

 

CLEAR

P

TER

OFF

R

 

ESS TOEN

 

NTOSEL

START

UR

ECT

T

 

PAUSE

 

 

CLEAR

P

TER

OFF

R

 

ESS TOEN

 

Step 2:

Turn the dial to select the type of food category you want. Press the dial to enter it.

Step 3:

Turn the dial to select the specific food. Press the dial to enter it.

Step 4:

Turn the dial to select the amount, size, and/or doneness (if required, the oven will prompt you). Press the dial after each selection.

Step 5:

Once the display shows ADJUST TIME OR START, either press the dial or start button to start cooking.

Press CLEAR/OFF at any time to stop cooking.

must always be in place when using the oven.

Put food directly on the black

metal tray to speedcook.

As a great option, put food directly on the black grill tray to speedcook foods you would normally cook on the grill.

Microwaving with Micro Express

SPEED

POWER

TIMER

MICRO

 

COOK

LEVEL

WAVE

 

REPEAT LAST

 

 

 

OVEN LIGHT

 

BACK

MANUAL

OPTIONS

HELP

MICRO

 

COOK

EXPRESS

 

RECIPE

 

 

 

 

 

 

RN

TOS

ELEC

TU

T

P

TER

R

ESS TOEN

Press MICRO EXPRESS repeatedly

for 30 second increments of microwave cooking time.

The oven starts immediately.

START

PAUSE

CLEAR

OFF

The oven rack (turntable)

must always be in place when using the oven.

The white ceramic tray should always be in place

10

when microwaving.

Image 10
Contents Advantium Oven Important Safety Instructions Safety Precautions Arcing Foods Microwave- safe Follow these guidelinesSafety Precautions Troubleshooting Tips first, you may not Read this manual If you Need serviceProblems in the Before You Call For Service Customer InformationWhat is Advantium? Getting to know AdvantiumBegin speedcooking Advantium Quick StartSet the clock Microwaving with Micro ExpressSpeedcook Menu Guide Display promptsPre-set speedcook menu selections Oven Features Oven featuresCooking controls SPEEDCOOK/REPEAT LastSpeedcooking Using speedcook featuresTo review settings during cooking, press the selector dial To use a pre-set speedcook menuCooking tips for great tasting results Resume featureRepeat last Speedcook power level Manual speedcook Place food directly on the black trays when cookingSpeedcook cookware Display will prompt you to selectSpeedcook recipe- to find and use Speedcook recipe- to enter and saveTo find and use stored custom speedcook recipes Speedcook recipe- to delete Speedcook recipe- to adjust or changeTo adjust or change stored custom speedcook recipes To delete stored custom speedcook recipesCustom Cook Custom speedcook recipesRecipe Name Time Things that Are normalMicrowaving Using the microwave featuresHow to use pre-set microwave selections DayTime Cook Microwave power levelHere are some examples of uses for various power levels Micro ExpressCustom Microwave recipe- to enter and saveMicrowave recipe- to find and use MicrowaveAdjust Time or Start appears Microwave recipe- to adjust or changeTo adjust or change stored custom microwave recipes Microwave recipe- to deleteTime defrost Power level is automatically set atAuto defrost Use Time Defrost to defrost for a selected length of timeDefrosting tips Microwave sensor cooking Covered VentedTo use all sensor programs Things that are normal InterferenceMicrowaving Review Other Advantium FeaturesFeatures under Options button Press the selector dial duringHelp Turn the dial to select the featurePress the Help button Child lock-out TimerAutomatic fan Helpful hints Care and CleaningHow to clean the inside Removable oven rack turntableUpper halogen lamp cover Baking sheets cooking traysHalogen lamp covers For heavy or burned on soilHow to clean the outside Do not use a steel wool pad it will scratch the surfaceQuestions? Use this problem solver TroubleshootingLighted yet oven Display is blankDisplay Control display is Will not startAdvantium Oven GE Service Protection Plus No Matter What BrandConsumer Product Ownership Registration Advantium Oven Warranty Warrantor General Electric Company. Louisville, KYGE Appliances Web site Schedule Service Consumer Support

SCB2000, SCB2001 specifications

The GE SCB2000 and SCB2001 are advanced digital protective relay systems designed for a variety of applications in the electrical power industry. These devices are recognized for their robust capabilities in protection, control, and monitoring of electrical distribution systems.

One of the primary features of the SCB2000 and SCB2001 is their comprehensive protection functionality. They are equipped to handle overload, short circuit, and earth fault protection for transformers, motors, and feeders. The advanced algorithms incorporated in these relays allow for precise detection and isolation of faults, minimizing downtime and enhancing system reliability.

These devices leverage state-of-the-art technology, including microprocessor-based controls, which ensure high performance and flexibility. The GE SCB relays are designed for easy integration into existing systems owing to their modular architecture. This functionality supports various communication protocols, including DNP3, IEC 61850, and Modbus, enabling seamless interaction with SCADA systems and other automation frameworks.

In terms of characteristics, the SCB2000 and SCB2001 provide extensive event and fault recording capabilities. They can capture a wealth of data before, during, and after events, offering valuable insights into system performance and facilitating effective troubleshooting. The user-friendly interface, typically featuring a color LCD display, allows operators to easily access critical information and configure settings.

Safety is paramount in the design of these devices. GE has implemented comprehensive self-diagnostic features that continuously monitor the relay’s health and operational status. This ensures that any potential issues are identified and addressed proactively, further reducing the risk of system failure.

Energy efficiency is another hallmark of the SCB2000 and SCB2001 series. With their intelligent design, these relays help optimize load management and energy distribution, contributing to lower operational costs for utility providers and industrial plants alike.

In conclusion, the GE SCB2000 and SCB2001 protective relay systems stand out for their versatility, advanced protective features, and seamless integration capabilities. With a focus on reliability, safety, and efficiency, these devices empower utilities and industries to enhance their electrical systems' performance, ensuring continuous and secure operation.