APPLICATIONS
Figures 3 through 6 show how to use the transceivers in various applications. Always connect + to + and - to -. The TW3032P is used as an example in Figures 3 through 6.
Table A shows the distance in feet with Coaxitron or video only when using a particular type of Cat cable. Table B shows the maximum allowable wire gauge for single wire and stranded wire.
Table A. Cable Distance
Cable Type | Distance | Distance | |
(with Coaxitron) | (video only) | ||
| |||
|
|
| |
Cat3 | 300 ft | 400 ft | |
|
|
| |
Cat5 | 500 ft | 650 ft | |
|
|
| |
Cat5e | 750 ft | 750 ft | |
|
|
| |
Cat6 | 750 ft | 750 ft | |
|
|
|
NOTE: Cat5e cable is recommended for optimum video performance.
Table B. Wire Gauge
Wire Gauge (maximum allowable)
Single Wire (solid) | 24 AWG (1.5 mm2) |
Stranded Wire (flexible) | 24 AWG (1.0 mm2) |
FIXED CAMERA
+
+
-
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TW3032P |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 |
MONITOR
UTP
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TW3032P |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 |
Figure 3. Connecting Two Transceivers