Alignment and Adjustments
5-4 High Voltage Capacitor
1.Check continuity of the capacitor with the meter set at the highest resistance scale.
2.Once the capacitor is charged, a normal capacitor shows continuity for a short time, and then indicates 9MΩ.
3.A shorted capacitor will show continuous continuity.
4.An open capacitor will show constant 9MΩ.
5.Resistance between each terminal and chassis should read infinite.
5-5 High Voltage Diode
1.Isolate the diode from the circuit by disconnecting its leads.
2.With the
check the
the other direction.
5-6 Main Relay and Power Control Relay
1.The relays are located on the PCB Ass'y. Isolate them from the main circuit by disconnecting the leads.
2.Operate the microwave oven with a water load in the oven. Set the power level set to high.
3.Check continuity between terminals of the relays after the start pad is pressed.
Precaution
For continued protection against radiation hazard, replace parts in accordance with the wiring diagram and be sure to use the correct part number for the following switches: Primary and door sensing switches, and the interlock monitor switch (replace all together). Then follow the adjustment procedures below. After repair and adjustment, be sure to check the continuity of all interlock switches and the interlock monitor switch.
1.When mounting Primary switch and Interlock Monitor switch to Latch Body, consult the figure.
2.No specific adjustment during installation of Primary switch and Monitor switch to the latch body is necessary.
3.When mounting the Latch Body to the oven assembly, adjust the Latch Body by moving it so that the oven door will not have any play in it. Check for play in the door by pulling the door assembly. Make sure that the latch keys move smoothly after adjustment is completed. Completely tighten the screws holding the Latch Body to the oven assembly.
4.Reconnect to Monitor switch and check the continuity of the monitor circuit and all latch switches again by following the components test procedures.
5.Confirm that the gap between the switch housing and the switch actuator is no more than 0.5mm when door is closed.
Primary Interlock Switch
|
|
|
| Interlock Monitor | ||
|
|
|
| Switch | ||
Body Latch |
|
|
|
|
| Lever Door |
|
|
|
|
| ||
|
|
| Door Sensing | |||
|
| |||||
|
|
|
| |||
|
|
|
| Switch | ||
|
|
|
|
|
|
|
|
|
| Door Open | Door Closed | ||
|
|
|
|
|
|
|
Primary switch |
| ∞ | 0 | |||
Monitor switch | 0 |
| ∞ | |||
Door Sensing S/W |
| ∞ | 0 | |||
|
|
|
|
|
|
|
Samsung Electronics |