Thermador PRD486GDHU manual PRO hARMONY Ranges PLANNiNG iNFORMATiON, Model OPTiONS

Page 5

PRO hARMONY® RANGES PLANNiNG iNFORMATiON

MODEL OPTiONS

There are three sizes of Thermador Pro Harmony Ranges to choose from—30-inch, 36-inch and

48-inch. 30 and 36-inch models are available in your choice of all-gas or dual-fuel configurations while the

48-inch model is available in dual-fuel. All models are a compact, 24-inch deep design and available in stainless steel with porcelain cooktop surface. Dual-fuel models are LP convertible by ordering PALPKITHC. All-gas models are available in Natural Gas or Liquid Propane and should be ordered separately from the factory. Be sure to reference the correct model information in this design guide.

iNSTALLATiON cONSiDERATiONS

The information in this design guide provides key features, product dimensions, cutouts and installation specifications. Before installing a Thermador Pro Harmony Range, be sure to verify the cutout dimensions and electrical/gas connections. Also, always consult with the installation manual packed with the product for complete details before installing.

ELEcTRicAL AND GAS SPEciFicATiONS

Be sure your appliance is properly installed and grounded by a qualified technician. Installation, electrical and gas connections, and grounding must comply with all applicable local codes.

GAS REQuiREMENTS AND hOOkuP

Verify that the type of gas being used at the installation site matches the type of gas used by the appliance.

If an LP kit is utilized (PALPKITHC), conversion from natural gas to propane must be done by qualified service personnel only. Please refer to the LP Conversion Instructions packed with product for further information.

A manual gas shutoff valve must be installed external to the appliance, in a location accessible from the front, for the purpose of shutting off the gas supply. The supply line must not interfere with the back of the unit.

NATuRAL GAS REQuiREMENTS:

Inlet Connection: 3/4" NPT external, 1/2" NPT internal (Minimum 3/4" diam. flex line.)

Supply Pressure: 6" min. to 14" max. water column. (14.9 mb to 34.9 mb)

Manifold Pressure: 5" water column (12.5 mb)

PROPANE GAS REQuiREMENTS:

Inlet Connection: 3/4" NPT external, 1/2" NPT internal (Minimum 3/4" diam. flex line.)

Supply Pressure: 11" min. to 14" max. water column. (27.4 mb to 34.9 mb)

Manifold Pressure: 10" water column (24.9 mb)

DuAL-FuEL:

Thermador Pro Harmony Dual-Fuel Ranges are dual rated, designed to be connected to either 208/240V AC, 60 Hz, 4 wire, single-phase power supply. The connection may be made with a range supply cord kit (purchased separately) or by hard-wiring to the power supply. A dedicated circuit breaker is required.

MODEL

REQuiRED ciRcuiT BREAkER

 

240/208V AC, 60 Hz

 

 

PRD304GHu

35 Amp

 

 

PRD364GDHu

35 Amp

 

 

PRD366GHu

35 Amp

 

 

PRD486GDHu

50 Amp

 

 

ALL-GAS:

Thermador Pro Harmony All-Gas Ranges are equipped with a 3-prong plug and are designed to be connected to a 120V AC, 60 Hz, single-phase power supply. A dedicated circuit breaker is required.

MODEL

REQuiRED ciRcuiT BREAkER

 

120V AC, 60 Hz

 

 

PRG304GH

15 Amp

 

 

PRL304GH

15 Amp

 

 

PRG366GH

15 Amp

 

 

PRL366GH

15 Amp

 

 

PRG364GDH

20 Amp

 

 

PRL364GDH

20 Amp

 

 

important:

The cord supplied with gas ranges having an electric griddle requires a NEMA 5-20 receptacle as shown here. Local codes may require a different wiring method. A dedicated 20 Amp service is required for proper operation.

PLUG

NEMA 5-20

RECEPTACLE

44

Image 5
Contents Inch PRO hARMOnY RAnGE Model PRD486GDhU ShOWn THERMADOR.COM PRO hARMONY RangesOUR EXCLUSIVE, PaTEnTED STaR BURnER PRO HaRmOny RanGES FEaTURES & BEnEFITSTRuLY FLuSh MOuNTED Range ELEcTRicAL and GAS SPEciFicATiONS INSTALLATiON cONSiDERATiONSPRO hARMONY Ranges PLANNiNG iNFORMATiON Model OPTiONSIMPORTANT VENTiLATiON Notes ELEcTRicAL and GAS LOcATiONSVENTiLATiON REQuiREMENTS PRO HARmOny RAnGES 30-InCHDUAL-FUEL SPECIFICAtIOnSPRD304GHU PRD304GHUInch CuTOuT and Range Dimensions INSTALLATiON OPTiONSBAckGuARD NATuRAL GAS or LPProfessional PRO HARmONy Ranges 36-INcHDUAL-FUELPRD364GDHU PRD364GDHUMin PRD366GHU PRD366GHUPRO hARMONY Ranges 36-iNchDuAL-FuEL PRD486GDHU PRO HaRmOny RanGES 48-InCHDUaL-FUELPRD486GDHU 447/8 PRO HaRmOny RanGES 30-InCH GaS ACCESSORIESPRG304GH / PRL304GH PRG304GH PRL304GHPRO hARMONY Ranges 30-iNch GAS PRG366GH / PRL366GH PRO HaRmOny RanGES 36-InCH GaSPRG366GH PRL366GH PRG366GH / PRL366GHMin PRG364GDH PRL364GDH PRG364GDH / PRL364GDHPRG364GDH / PRL364GDH Pa36GLBH PWOKRInGHC Pa12GCvRHC PaKnOBLKPRO HaRmOny RanGES 36-InCH GaS