Thermador PRD486GDHU manual ELEcTRicAL and GAS LOcATiONS, VENTiLATiON REQuiREMENTS

Page 6

ELEcTRicAL AND GAS LOcATiONS

Typical placement of the electrical and gas supply can be found within the “Cutout and Range Dimensions” located on the product pages. Alternate placement within the supply zone is acceptable. Dual-Fuel ranges may be connected to the power supply with a range supply cord kit (sold separately) or by hard-wiring to the power supply. All-Gas ranges may be connected to the power supply with the supplied range cord or by hard-wiring. It is the responsibility of the installer to provide the proper wiring components (cord or conduit and wires) and complete the electrical connection as dictated by local codes and ordinances and/or the National Electric Code. The units must be properly grounded.

Installation of the range must be planned so that the rough-in of the junction box for the receptacle or conduit connection will allow maximum clearance to the rear of the unit.

WARRANTY

Limited warranty parts and labor (1 year) See page 294 for additional warranty details.

Warning: All ranges can tip, causing injury. Install anti-tip device packed with range.

Thermador Pro Grand® Ranges are CGA, CSA and

AGA approved.

S

 

DE IGN

 

C E R TIFIED

PRO hARMONY® RANGES PLANNiNG iNFORMATiON

VENTiLATiON REQuiREMENTS

We strongly recommend that a Thermador Professional Wall or Island Hood or Custom Insert be installed with all Thermador Pro Harmony Ranges. Downdraft ventilation should not be used. Do not install a microwave-hood combination above the cooktop, as these types of units do not provide the proper ventilation and are not suitable for use with Thermador Pro Harmony Ranges.

For high output gas cooktops (60,000 BTu or greater), the minimum of one

(1)CFM of ventilation per 100 BTu is recommended. If the cooktop has a grill or griddle, add 200 CFM to the estimated blower capacity. Additional blower capacity may be required for longer duct runs.

The following table indicates the ventilation hood options that are recommended for use with Thermador Pro Harmony Ranges. Refer to the Ventilation section or www.Thermador.com for a complete selection of Professional ventilation options, blowers, and accessories.

WiDTh

cONFiGuRATiON

VENTiLATiON OPTiONS

 

 

 

 

 

 

 

30" or 36" Pro Wall Hood

30"

 

4 Burners

30" or 36" Custom Insert

 

w/optional blower

 

 

 

 

 

 

42" Island Hood w/optional blower

 

 

 

 

 

4

Burners w/Grill or

36" or 42" Pro Wall Hood

36"

 

Griddle

36" Custom Insert w/optional blower

 

 

42" or 48" Island Hood w/optional

 

 

 

 

 

6 Burners

blower

 

 

 

 

 

6

Burners w/Grill or

48" or 54" Pro Wall Hood

48"

48" Custom Insert w/optional blower

 

Griddle

 

 

54" Island Hood w/optional blower

 

 

 

 

 

 

 

iMPORTANT VENTiLATiON NOTES:

Due to the high surface temperature output of the Pro Harmony Ranges, the HPWB Professional Series Wall Hoods or the Professional Series Custom Inserts are recommended ventilation solution for these ranges. The PH Professional Series Wall Hoods are also a viable option, however the 27" depth of the PH Series may not be suitable to all applications.

For wall installations, the hood width must, at a minimum, equal the nominal width of the appliance cooking surface. Where space permits, a hood larger in width than the cooking surface may be desirable for improved ventilation performance.

For island installations, the hood width should, at a minimum, overhang the appliance cooking surface by 3" on each side.

Due to the high heat capability of these cooktops, particular attention should be paid to the hood and duct work installation to assure it meets local building codes.

For best smoke elimination, the lower edge of the hood should be installed 30"– 36" above the appliance cooking surface.

If the hood contains any combustible materials (i.e., a wood covering), it must be 40"or greater distance above the cooking surface.

PRO hARMONY RANGES

1.800.735.4328 THERMADOR.COM

45

 

Image 6
Contents Inch PRO hARMOnY RAnGE Model PRD486GDhU ShOWn PRO hARMONY Ranges THERMADOR.COMPRO HaRmOny RanGES FEaTURES & BEnEFITS OUR EXCLUSIVE, PaTEnTED STaR BURnERTRuLY FLuSh MOuNTED Range PRO hARMONY Ranges PLANNiNG iNFORMATiON INSTALLATiON cONSiDERATiONSELEcTRicAL and GAS SPEciFicATiONS Model OPTiONSELEcTRicAL and GAS LOcATiONS VENTiLATiON REQuiREMENTSIMPORTANT VENTiLATiON Notes PRD304GHU SPECIFICAtIOnSPRO HARmOny RAnGES 30-InCHDUAL-FUEL PRD304GHUBAckGuARD INSTALLATiON OPTiONSInch CuTOuT and Range Dimensions NATuRAL GAS or LPPRD364GDHU PRO HARmONy Ranges 36-INcHDUAL-FUELProfessional PRD364GDHUMin PRD366GHU PRD366GHUPRO hARMONY Ranges 36-iNchDuAL-FuEL PRO HaRmOny RanGES 48-InCHDUaL-FUEL PRD486GDHUPRD486GDHU 447/8 PRG304GH / PRL304GH ACCESSORIESPRO HaRmOny RanGES 30-InCH GaS PRG304GH PRL304GHPRO hARMONY Ranges 30-iNch GAS PRG366GH PRL366GH PRO HaRmOny RanGES 36-InCH GaSPRG366GH / PRL366GH PRG366GH / PRL366GHMin PRG364GDH / PRL364GDH PRG364GDH / PRL364GDHPRG364GDH PRL364GDH Pa36GLBH PWOKRInGHC Pa12GCvRHC PaKnOBLKPRO HaRmOny RanGES 36-InCH GaS