Applicable to Models: CFD-1F, CFD-2F, CFD-3F
ColdTech® Freezer Settings
Temperature set to |
|
|
| |
Parameter | Function | Set Range | Default | |
E1 | Lower Setpoint Limit | |||
E2 | Higher Setpoint Limit | set temp ~ 120 F | 20 F | |
E3 | Hysteresis, temp variance | 1 | ~ 18 F | 10 F |
E4 | Comp. start delay time | 0 | ~ 10 min. | 3 min. |
E5 | Offset on room temp | 0 F | ||
E6 | Offset on evap temp | 0 F | ||
F1 | Max. defrost duration | 1 | ~ 60 min. | 30 min. |
F2 | Defrost interval time | 0 | ~ 24 hr. | 6 hr. |
F3 | Defrost termination temp | 32 ~ 68 F | 68 F |
Key
F = Farenheit (degrees) | temp = temperature |
min. = minutes | max = maximum |
hr. = hours | N/A = not applicable |
Warning:
Do not change the default settings of your ColdTech unit without consulting a qualified service technician or the ColdTech service department.