TROUBLESHOOTING GUIDE
This section contains information intended for use by Authorized Service Personnel only.
PROBLEM
A/ Kettle heats too slowly or does not come to a boil.
Probable Cause | Remedy |
1. Inadequate steam flow. | Check for correct steam using chart below. |
| If kettle is connected to a steamer and powered by a generator the units |
| should be operated sequentially (kettle boiling first, then start steamer). |
2.Steam trap not operating properly.
3.Food batches are not always the same.
PROBLEM
B/ The trunnion housing leaks steam.
Probable Cause
1.Trunnion "O" rings are worn.
The trap should open periodically to dump condensate, then close. If it does not open or close it should be cleaned or replaced.
When checking make certain that the original state (ie. fresh or frozen) and quantity of food product is the same.
Remedy
Replace "O" rings
PROBLEM
B/ The steam trap makes a banging noise when steam applied to cold kettle.
Probable Cause | Remedy |
1.Kettle condensate has not been drained.
On all tilting models the condensate should be drained from the cold kettle. This is done before steam is applied using the drain cock valve on the bottom of the kettle.
WIRING DIAGRAM
Power Tilt Units Only
115 Volts, 1PH, 50/60HZ