Refer to the serial plate for correct electrical rating. The power cord of the appliance is equipped with a three-prong grounding plug for protection against shock hazards. It must be plugged directly into its own properly grounded three-prong receptacle, protected with a 15 amp time delay fuse or circuit breaker. The receptacle must be installed in accordance with the local codes and ordinances. Consult a qualified electrician. Receptacles with Ground Fault Circuit

Interrupters (GFCI) are NOT RECOMMENDED. DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG.

If the voltage varies by 10 percent or more, appliance performance may be affected. Operating the appliance with insufficient power can damage the motor. Such damage is not covered under the warranty. If you suspect your voltage is high or low, consult your power company for testing.

To prevent the appliance from being turned off accidentally, do not plug the unit into an outlet controlled by a wall switch or pull cord.

DO NOT pinch, knot, or bend the power cord in any manner.

Other Precautions

NEVER unplug the appliance by pulling on the power cord. Always grip the plug firmly and pull straight out from the receptacle.

To avoid electrical shock, unplug the appliance before cleaning.

NOTE: Turning the control to "OFF" turns off the compressor but does not disconnect power to other electrical components.

UNCRATING AND SET-UP

Remove carton and all loose parts from inside of the unit.

Carefully tip the unit onto its back with the help of an assistant. Lay the unit gently to rest on blocks to avoid damaging the condensate drain hose and the plastic

raceway that covers the evaporator tubing on the back of the cabinet.

Remove and discard the wood skid from the bottom and the four (4) screws using a 3/8" socket wrench (see Fig. 1).

Using a large adjustable wrench, remove and discard the

two (2) black plastic leg levelers by turning it

counterclockwise (see Fig. 2).

CASTER INSTALLATION & SETUP

INSPECTION FOR DAMAGE

Inspect the underside of the cabinet and packaging for damage such as a fork truck can cause. If hidden damage is found after uncrating immediately call the delivery carrier and request an inspection. Retain atl packaging and crating materials until the inspection is complete.

PARTS AND ACCESSORIES

Check to make sure that you have received the box containing all of the components listed below.

DF

/

EG

ACASTER RAIL (2 /

BTAPPING PLATE (2)

CBOLT (6)

DWASHER (6)

TOOLS NEEDED

You wilI need the following tools to assemble and install the casters to the

unit. _ _i_

3/8" AND t/2" INCH

ADJUSTABLE WRENCH

1/2" iNCH FIXED

SOCKET WRENCH

OR PLIERS

WRENCH

UNCRATING AND SET-UP

Remove carton and all loose parts from inside of the unit.

Carefully tip the unit onto its back with the help of an assistant. Lay the unit gently to rest on blocks to avoid damaging the condensate drain hose and the plastic raceway that covers the evaporator tubing on the back of the cabinet,

Remove and discard the wood skid from the bottom and the four (4) screws using a 3/8" socket wrench (see Fig. 1 )

Using a large adjustable wrench remove and discard the two (2) black plastic leg levelers by turning it counterclockwise (see Fig. 2)

SCREWS

WOOD SKID

Figure 2

Figure 1

Image 3
Contents Arctic AIR Commercial REFRIGERATOR/FREEZER Important Safety Instructions Product RegistrationBefore YOU Throw Away Your OLD REFRIGERATOR/FRE Ezer Inspection for Damage Parts and AccessoriesAdjustable Wrench Uncrating and SET-UPAlignthecasterrailassemblywiththerighthandsideoftheunit Front Swivel Caster InstallationAppliance Start-Up BackofUnit FeaturesReversing Door Routine MaintenanceDoor Lock GeiiiEnergy Conservation Measures Appliance does not RUN Avoid Service ChecklistLamp is not on Odor in Appliance Door ProblemsSound and Noise WATER/MOISTURE/FROST Inside ApplianceCompressor Re Control Compressor YelAvoid Unnecessary Cost and Inconvenience If Service Is NecessaryFood Loss NON-FACTORY Approved Revisions or Modifications Arctic AIR Commercial REFRIGERATOR/FREEZER Warranty

Refrigerator specifications

The Arctic Air Refrigerator is a popular choice in both commercial and residential settings, known for its reliability, efficient cooling technology, and user-friendly features. Designed to cater to the needs of various industries such as food service, supermarkets, and home use, Arctic Air refrigerators showcase a robust blend of performance and functionality.

One of the main features of Arctic Air refrigerators is their advanced cooling system, which utilizes a high-efficiency refrigeration system. This system not only ensures optimal temperature control but also promotes energy efficiency, helping users save on electricity costs. The refrigerators are capable of maintaining temperatures consistently between 32°F and 41°F, making them ideal for preserving perishable goods.

In addition to the efficient cooling mechanism, Arctic Air refrigerators also boast durable construction. They are typically constructed with high-quality stainless steel, ensuring longevity and resistance to rust and corrosion. This makes them suitable for environments where durability is crucial, such as commercial kitchens and laboratories.

Another standout characteristic is the user-friendly design. Many models come equipped with adjustable shelves, allowing for easy customization of space to accommodate various items. The shelves are often made from sturdy materials that can support heavy loads, further enhancing the refrigerator's versatility.

Arctic Air refrigerators also feature advanced temperature control systems, including digital control panels that allow users to monitor and adjust the settings with precision. This technology provides visual feedback, ensuring that the optimal temperature is maintained without constant manual adjustments.

Additionally, the refrigerators are designed with energy efficiency in mind, often surpassing strict energy regulations. Many models incorporate environmentally friendly refrigerants that contribute to lower emissions, making Arctic Air a sustainable choice for the eco-conscious consumer.

The ease of maintenance is another significant advantage. With removable gaskets and easy-to-clean surfaces, routine upkeep is straightforward, ensuring that the units remain hygienic and efficient over long periods of use.

Finally, Arctic Air refrigerators often come with advanced ventilation systems to promote air circulation, preventing hot spots and ensuring uniform cooling throughout the unit. This characteristic not only enhances food safety but also extends the shelf life of perishable products.

In summary, Arctic Air refrigerators stand out for their efficiency, durability, and user-friendly features, making them an excellent choice for anyone seeking a reliable refrigeration solution.